background image

Installation and Operation Instructions

Universal Outdoor Vent-Free Firebox
With Refractory Panels

VRE4536WS 

VRE4536WH

VRE4542WS 

VRE4542WH

VRE4550WS 

VRE4550WH

P127029-01

SAVE THIS BOOK

This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information 

that will enable you to obtain replacement parts or accessory items when needed. Keep it with your other important papers.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

 WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam-

age. Refer to this manual for correct installation and operational procedures. For assistance or additional information 

consult a qualified installer, service agency or the gas supplier.

This fireplace is approved for use on an outdoor application provided that a certified gas log set approved under the 

ANSI Z21.97 standard with a maximum input rate of 40,000 BTU's is used. 

An IHP hood must be installed when using 

a vent-free log heater 

(see Parts, Page 15).

DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS 

REQUIRED FOR THE INSTALLATION.

   WARNING: FOR USE ONLY WITH A LISTED, GAS-FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 

40,000 BTU/H.
DO NOT BUILD A WOOD FIRE.

Models

P/N 127029-01  REV.  F  01/2019

Report No. F09-130

PFS

®

US

C

 -  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 

•  Do not touch any electrical switch; do not use 

any phone in your building. 

•  Leave the building immediately.

•  Immediately call your gas supplier from a neigh-

bor’s phone.  Follow the gas supplier’s instruc-

tions. 

•  If you cannot reach your gas supplier, call the 

fire department.

 -  Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.

       WARNING:
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could 

result in serious injury, death, or property damage.

        AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION

Le non-respect Des avertissements de sécurité pourrait 

d’entraîner des blessures graves, la mort ou des dom-

mages matériels.

 -   Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs 

ou liquides inflammables dans le voisinage de cet appareil 

ou de tout autre appareil.

 -  QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:

• Ne pas tenter d’allumer d’appareil.

• Ne touchez à aucan interrupteur. Ne pas vous servir des 

téléphones se trouvant dans le bâtiment où vous trouvez. 

•  Sortez immédiatement de bâtiment.

• Appelez immédiatement votre fournisseur de gaz depuis 

un voisin. Suivez les instructions du fournisseur. 

• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez 

le service des incindies.

 -  L’installation et l’entretien doivent être assurés par un 

installateur ou un service d’entretien qualifié ou par le 

fournisseur de gaz.

Содержание VRE4500

Страница 1: ...N 127029 01 REV F 01 2019 Report No F09 130 PFS US C Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do n...

Страница 2: ...ck which is known totheStateofCaliforniatocausecancer andCarbon Monoxide which is known to the State of California tocausebirthdefectsorotherreproductiveharm For more information go to www P65Warnings...

Страница 3: ...appliances are approved for installation in the US state of Massachusetts if the following additional requirements are met Un vented Room Heaters shall be installed in accordance with 527 CMR 30 Insta...

Страница 4: ...F 4 PRODUCT SPECIFICATIONS 36 MODELS Figure 1 36 Models VRE4536RS VRE4536WS VRE4536RH and VRE4536WH 20 1 4 Ref 1 1 4 22 1 2 19 36 HEARTH 29 30 1 2 30 36 54 1 2 11 1 8 45 1 8 36 3 8 35 1 4 9 1 2 3 3 8...

Страница 5: ...RODUCT SPECIFICATIONS continued 42 MODELS Figure 2 42 Models VRE4542RS VRE4542WS VRE4542RH and VRE4542WH 42 HEARTH 21 3 4 8 3 4 3 3 8 9 1 2 26 3 8 41 3 8 4 7 8 1 1 4 3 3 4 32 3 8 36 3 8 11 1 8 7 7 8 5...

Страница 6: ...6 Figure 3 50 Models VRE4550RS VRE4550WS VRE4550RH and VRE4550WH 21 3 4 8 3 4 9 1 2 3 3 8 13 50 50 7 30 34 3 8 38 3 8 4 7 8 49 3 8 36 3 8 59 1 8 54 1 2 11 1 8 3 3 4 32 3 8 7 7 8 23 Ref 50 HEARTH PRODU...

Страница 7: ...x Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z223 1 NFPA54 allows two meth ods for determining whether the space in which the heater is being installed is confined or uncon...

Страница 8: ...ned space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces se...

Страница 9: ...ottom of your firebox except where standoff spacers are integrally attached If standoff spacers are attached to your firebox these spacers can be placed directly against wall or framing materials Use...

Страница 10: ...ational product standard Fol low all minimum clearances shown in this manual NOTICE Ifyourinstallationdoesnotmeettheminimum clearances shown you must do one of the following raise the mantel to an acc...

Страница 11: ...es This firebox may be installed using a cabinet mantel against a wall in your home The firebox and cabinet mantel can be installed directly on the floor Mantels may be available from your retailer or...

Страница 12: ...he right and left refractory panels with the gas line knock outs orientated down toward the bottom refractory Align the left and right panels with the rear panel so the grout lines line up 5 Install t...

Страница 13: ...l furnace cement Install the gas appliance or cap off gas line if desired A gas line or gas log lighter may be installed for the purpose of installing a vent free decorative gas appliance incorporatin...

Страница 14: ...1 20 1 19 5 14 15 16 13 12 11 9 7 6 8 17 2 12 18 4 PARTS MODEL NO CAT NO INTERIOR VRE4536WS F0474 White Stacked VRE4536WH F0476 White Herringbone VRE4542WS F0478 White Stacked VRE4542WH F0480 White He...

Страница 15: ...EPLACE 36 1 RP110454 02 TOP FIREPLACE 42 1 RP110454 01 TOP FIREPLACE 50 1 9 J6997 SPACER FIREPLACE TOP 42MC 4 10 FIREPLACE SURROUND ASSEMBLY 1 11 J4362 SPACER CLEARANCE 36 42 50 6 12 J5329 BRACKET F P...

Страница 16: ...itute materials not approved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 5 3 4 6 6 IMPORTANT Installation of brick panels should be done after the fireplace...

Страница 17: ...ORY HEARTH 36 STD WHITE 1 REFRACTORY HEARTH 42 STK WHITE 1 REFRACTORY HEARTH 50 STK WHITE 1 3 REFRACTORY RIGHT 36 STK WHITE 1 REFRACTORY RIGHT 36 HER WHITE 1 REFRACTORY RT 42 STK WHITE 1 REFRACTORY RT...

Страница 18: ...ler Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the fireplace 2 The serial number of the fireplac...

Страница 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 20: ...ributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 127029 01 Rev F 01 2019 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us com Record the...

Отзывы: