OPERATIONAL MANUAL
FOR
CONTROLLER SC91T
www.fujicon.com.sg
1
Страница 1: ...OPERATIONAL MANUAL FOR CONTROLLER SC91T www fujicon com sg 1 ...
Страница 2: ...tents Page 1 Introduction 1 2 Precaution 2 3 Specifications 3 4 Features 4 5 Input Output circuit 5 6 Control Panel and function 7 7 Preparation 9 8 Operation 10 9 Controller layout 11 www fujicon com sg 2 ...
Страница 3: ...lly after read This is an all in one ultimate solution to all controller need It is a 9 in 1 controller It has 9 functions which out beat the other controller in the current market The functions are 1 Input Voltage Selection 2 NPN or PNP Selection for Sensor 3 NC or NO Operation Selection 4 3 kHz or 6 kHz Frequency Selection 5 Adjustable On Off Delay Timing 6 Adjustable Gain 7 Adjustable Output Vo...
Страница 4: ... by the parts feeder after being modified or additionally processed by a third party other than the manufacturer after delivery Specifications and contents of this manual are subject to change without any obligation part of the manufacturer DANGER Electric shock Turn OFF primary power source before any wiring and maintenance DANGER Electric shock Connect the grounding wire green yellow before sett...
Страница 5: ...e Switch 2 Selects Sensor NPN or PNP Selection Switch 3 Selects Operation NC or NO Switch 4 Selects Frequency 3kHz or 6kHz External VR1 Adjusts OFF Delay Setting VR2 Adjusts ON Delay VR3 Adjusts GAIN VR4 Adjusts Output Voltage Control Status Dry Contact Shorted Circuit when Feeder is Active Indicator Red Feeder Inactive Light Green Feeder Active Housing Dimension 97 5 x 47 x 150 mm L X B X H Case ...
Страница 6: ...F Delay VR1 The off delay is used to turn the feeder off in the adjusted time Example If the off delay is set to 5sec While the feeder is active if the sensor detects anything for 5sec it will turn the feeder off 4 6 2 ON Delay VR2 The on delay is used to turn the feeder on in the adjusted time Example If the on delay is set to 5sec While the feeder is not active if the sensor detects nothing for ...
Страница 7: ...V 12V SIG Connection in next page A FUSE Holder 2 5A 250V Insert fuse here Connect terminal with Live input Brown and output Neutral input Blue and output Ground input Green Yellow and output Out 1 and Out 2 Connection in next page B www fujicon com sg 7 ...
Страница 8: ...5 2 Terminal Connection 5 2 1 Sensor terminal A 5 2 2 Terminal B www fujicon com sg 8 ...
Страница 9: ...eases the time needed to turn on the output upon power on It is also advisable to proceed with the fine tunning of the ON delay to start the output immediately before any sensor is connected When this is achieved it will therefore be a guide to gauge how much to turn in order to achieve the desired delay operation when the sensor is connected In the event of operation with a sensor please connect ...
Страница 10: ...ON D Set the appropriate delay ON timing ON OFF Switch Switching power on and off GAIN To control the output voltage range Output Voltage Control VR4 to control output voltage from 0 10 Indicator light Indicate power is on Mounting dismounting screw x 2 Mounting hole www fujicon com sg 10 ...
Страница 11: ...e Selection Switch 3 Select NO or NC operation Switch 2 Select NPN or PNP sensor selection Switch 4 Select 3kHz or 6kHz frequency selection Switch 1 Select input voltage 230Vac or 115Vac www fujicon com sg 11 ...
Страница 12: ...which both side of the fuse must be in contact with the fuse holder 7 7 Sensor Insert the fiber optic cable to the fiber optic photoelectric sensor 7 8 Select SW1 for input voltage Check what the power supply voltage is and adjust to the correct setting 7 9 Select SW2 for PNP or NPN sensor Check whether the sensor is a PNP sensor or NPN sensor 7 10 Select SW3 for NC or NO operation Check whether y...
Страница 13: ...GAIN to Control Output Voltage Range Tune the gain potentiometer in the front panel to control the output voltage range Adjust VR4 to mid range example 5 turn VR3 to obtain optimum performance 8 5 Adjust VR4 Output Voltage Control to Control Output Voltage The output voltage control in the front panel is use to control the output voltage By turning clockwise the voltage will increase from 0 to 10 ...