background image

- 7 - 

 

 

Symbol Designations

:   

1. Indicates Data Hold 

2. Indicates the type of thermocouple 

3. Indicates IR measurement 

4. Emissivity 

5. Measurement Display area 

6. Measurement Display area 

7. Average/ Maximum / minimum Indicator   

8. Indicates laser pointer use 

9. Indication back light ON     

10.Temperature units   

11.Low battery indicator 

 

 Operating instructions 

1.  Press  the                  key  to  turn  the  unit  on.    Press 

the key again to shift the measurement mode between 

infrared or thermocouple. 

2.  While  in  Infra-red  mode,  press  the 

LASER 

key  to 

make  IR  measurements.  Point  the  laser  at  the  target 

TYPE

ON/OFF

Содержание EM90

Страница 1: ... 1 EM90 INFRA RED THERMOMETER THERMOCOUPLE METER Users Manual ...

Страница 2: ...te the meter as accurately and safely as possible This meter combines two precision thermometers in one unit a noncontact infra red thermometer and a thermocouple thermometer This meter can match standard type K type thermocouple sensor WARNING Do not point laser directly at eye or reflective surfaces 1 1 Precautions safety measures To get the best performance from this meter please read this user...

Страница 3: ...r to excessive ambient temperatures 3 Keep the thermometer clean 1 1 2 Maintaining the product l Do not measure in a high temperature high humidity locations l When not using the instrument for a long time please remove the battery and avoid storing in high temperature and high humidity Features 1 Display 4 digit LCD Display 2 Resolution 0 1 0 1 1 1 thermocouple above 1000 ...

Страница 4: ...1 5 reading 4 2 for 4 to 572 20 to 300 Thermocouple 0 2 reading 2 1 for 328 to 148 200 to 100 0 1 reading 0 7 1 4 for 148 to 2372 100 to 1300 5 Emissivity 0 95 6 Field of view 2 1 7 Laser power Less than 1 mw 8 Response time 0 5 second 9 Auto power off 25 seconds infrared or 20 minutes thermocouple 10 Low battery indicator ...

Страница 5: ...50 0 to 90 RH 12 Storage environment 14 to 140 10 to 60 0 to 80 RH 13 Dimensions 4 76 L x 2 36 W x 1 18 H 121mm L x 60mm W x 30mm H 14 Weight 6 35 oz app 180 g app 15 Accessories K type thermocouple wire 1 Lanyard 1 AAA Batteries 3 Users manual ...

Страница 6: ... 6 Instrument Description 1 Sensor cover 2 Infra red sensor 3 Thermocouple jack 4 LCD display 5 Function key l LCD Display LASER SCAN H TYPE UNIT MODE ON OFF Infrared temperature thermocouple meter ...

Страница 7: ...ge Maximum minimum Indicator 8 Indicates laser pointer use 9 Indication back light ON 10 Temperature units 11 Low battery indicator Operating instructions 1 Press the key to turn the unit on Press the key again to shift the measurement mode between infrared or thermocouple 2 While in Infra red mode press the LASER key to make IR measurements Point the laser at the target TYPE ON OFF ...

Страница 8: ...he SCAN H key again to return the measurement mode Function Keys 1 TYPE ON OFF Key ON OFF Press this key to turn the power ON and press the key again for more than 2 seconds to turn the power OFF TYPE Press this key to select infra red or thermocouple mode 2 key Turns back light on or off 2 UNIT key Press this key to select temperature units or ...

Страница 9: ...ss this key for Data Hold a icon will be displayed on the LCD Press the key once more to cancel the hold function 7 Auto power off setting The instrument is factory set for Auto Power Off The meter will power itself off after 25 seconds IR or 20 minutes thermocouple if no key is pressed To cancel the auto power off function press the LASER key whith power on until the LCD displays all icons and th...

Страница 10: ...ivity of 0 95 Measuring objects with an emissivity of less than 0 95 will result in a lower than actual temperature reading on the display Be aware of this characteristic when measuring low emissivity objects e g shiny reflective metal objects An effective solution is that using the black adhesive tape to cover the object surface taking the measurement when the adhesive tape s temperature is the s...

Страница 11: ...asurement target must fill or exceed the field of view Maintenance 1 CLEANING INSTRUCTIONS The meter may be wiped down with a wet sponge or cloth using a mild water based detergent NOTE This unit is not designed for complete submersion or washing in water 2 BATTERY REPLACEMENT Use the following procedure When the battery voltage drops below proper operation range the symbol will appear on ...

Страница 12: ...arts Co Inc warrants that it will repair or furnish without charge a similar product to replace any product which within the specified warranty term after the date of sale by the Wholesaler is proved to the satisfaction of Sealed Unit Parts Co Inc to have been defective at the time it was sold Said warranty is in effect only when said item is used in accordance with the instructions and recommenda...

Страница 13: ...liability in connection with its products is expressly limited to the repair or replacement of defective parts All other damages and warranties statutory or otherwise are being expressly excluded No representative of Sealed Unit Parts Co Inc has authority to change this warranty in any manner whatsoever No attempt to repair or promise to repair or improve any part covered by this warranty by any r...

Страница 14: ... 14 Sealed Unit Parts Company Inc SUPCO 2230 Landmark Place Allenwood NJ 08720 USA www supco com info supco com ...

Отзывы: