4.2. Data Format
(
Default
:
8N1
)
:
This setting determines the format of the data on the serial port.
The default is 8 data bits, No parity, and 1 Stop bit.
8N1
8E1
8O1
4.3. IP Protocol Config
(
Default
:
UDP Point to Point
)
:
This setting determines which protocol the serial server will use to transmit serial
port data over the TDD-COFDM network.The protocol selected in the IP Protocol
Config field will determine which configuration options appear in the remainder of
the
5. RS232 Configuration Menu.
TCP Client:
When TCP Client is selected and data is received on its serial port, the TDD-COFDM takes the initiative to find
and connect to a remote TCP server. The TCP session is terminated by this same unit when the data exchange session is
completed and the connection timeout has expired. If a TCP
connection cannot be established, the serial port data is discarded.
UDP Point-to-Point:
In this configuration the TDD-COFDM will send serial data to a specifically-defined point,using UDP
packets. This same TDD-COFDM will accept UDP packets from that same point.
Remote IP Address
IP address of distant device to which UDP packets are sent when data received at serial port.
Default:
192.168.55.2(master);192.168.55.1(slave).
Remote Port
UDP port of distant device mentioned above.
Default:
20002
Listening Port
UDP port which the IP Series listens to (monitors). UDP packets received on this port are forwarded to the unit’s serial port.
Default:
20002
UDP Timeout(s)
UDP Timeout in seconds.
Default:
10