4.2. Data Format

Default

8N1

:

This setting determines the format of the data on the serial port.
The default is 8 data bits, No parity, and 1 Stop bit.

8N1

8E1
8O1

4.3. IP Protocol Config

Default

UDP Point to Point

:

This setting determines which protocol the serial server will use to transmit serial
port data over the TDD-COFDM network.The protocol selected in the IP Protocol
Config field will determine which configuration options appear in the remainder of
the

5. RS232 Configuration Menu.

TCP Client:

When TCP Client is selected and data is received on its serial port, the TDD-COFDM takes the initiative to find

and connect to a remote TCP server. The TCP session is terminated by this same unit when the data exchange session is
completed and the connection timeout has expired. If a TCP
connection cannot be established, the serial port data is discarded.

UDP Point-to-Point:

In this configuration the TDD-COFDM will send serial data to a specifically-defined point,using UDP

packets. This same TDD-COFDM will accept UDP packets from that same point.

Remote IP Address

IP address of distant device to which UDP packets are sent when data received at serial port.
Default:

192.168.55.2(master);192.168.55.1(slave).

Remote Port

UDP port of distant device mentioned above.
Default:

20002

Listening Port

UDP port which the IP Series listens to (monitors). UDP packets received on this port are forwarded to the unit’s serial port.
Default:

20002

UDP Timeout(s)

UDP Timeout in seconds.
Default:

10

Содержание ST10NPT

Страница 1: ... Start Connecting Tdd cofdm equipment 8th 2 Restart TDD COFDM Control Panel software 8th 3 RF Configuration method 8th 3 1 TX Rate 9th 3 2 Channel Bandwidth 9th 3 3 Channel Frequency 9th 3 4 Wireless Distance 9th 3 5 RX TX Mode 9th 3 6 TX Power 10th 4 Seria Configuration method 10th 4 1 Data Baud Rate 10th 4 2 Data Format 10th 4 3 IP Protocol Config 11th 5 RS232 Configuration Menu 11th 6 IP New Ne...

Страница 2: ...e product is used all the contents of the disclaimer will be regarded recognized and accepted Please install and operate the product in strict accordance with the requirements of this manual SUNTOR ELECTRONICS CO LIMITED and its affiliates will not assume any legal responsibility for results or losses caused by improper use installation assembly and modification including the use of non specified ...

Страница 3: ...or blocking by obstacles The antenna end should be vertically downward without bending to prevent shortening of the communication distance and failure in communication as a result of blocking 4 The antennas of the onboard terminal should be separated from each other to achieve good anti jamming effects It should be kept far away from antennas of other onboard radio transmitters as huge electromagn...

Страница 4: ...nd terminal is OFF the built in radio receiver of the onboard terminal will be out of control 13 Pay attention to the angle and direction of the antenna of the ground terminal during flight In case of poor signal or image quality adjusting the inclination of the antenna of the ground terminal can improve the signal or image effect 14 The camera should be fully charged to ensure normal video output...

Страница 5: ...nd terminal x1 On board antenna x1 Ground antenna x1 4P to DC power cable x1 DC to DC power cable x2 Network cable x4 Serial port cable x1 Length 20cm Serial port cable x1 Length 1500cm USB cable of serial port 2 x1 VI Setup 1 Set the IP Address ...

Страница 6: ...ngs you can modify according to your own needs Factory Settings Port status Data Data Baud Rate 115200 Data Format 8N1 Data Mode Transparent character timeout 24 Maximum Packet Size 256 Bytes No Connection Data Enable DBUS TCP Status Disable IP Protocol Configure UDP Point to Point UDP Point to Point settings Remote IP Address Input TX with RX IP Address Input RX with TX IP Address Remote Port Def...

Страница 7: ...mmended to mount it vertically at the top of the UAV 3 The best installation location is the UAV ground bracket With the antenna inside the bracket can only use fiberglass material 4 If the ground bracket is automatically retracted the antenna can be installed in the lower part of the aircraft and the ground RX antenna is recommended to use same antenna with TX 29cm length antenna 5 If the antenna...

Страница 8: ...9cm long antenna The best installation position is the center of the UAV tail prominent outside the body and vertical downward 4 The second optional mounting position is located below the wing and body joints vertical down as far as possible away from the wing but near the machine abdomen protruding below the abdomen level VIII Software Operation 1 Start Connecting Tdd cofdm equipment First enter ...

Страница 9: ...e with a poor link may result in reduced performance 3 2 Channel Bandwidth Default 4Mhz Select the channel bandwidth from the list Refer to the specifications to see the relationship and performance between channel band width throughput and sensitivity Generally a larger channel has greater throughput at the cost of sensitivity while a smaller channel tends to be more robust but at the cost of thr...

Страница 10: ...ed to the antenna connector of the TDD_COFDM Unless required the Tx Power should be set not for maximum but rather for the minimum value required to maintain an adequate system fade margin 4 Seria Configuration method 4 1 Data Baud Rate Default 115200 The serial baud rate is the rate at which the modem is to communicate with the attached local asynchronous device 921600 460800 230400 115200 57600 ...

Страница 11: ... TCP server The TCP session is terminated by this same unit when the data exchange session is completed and the connection timeout has expired If a TCP connection cannot be established the serial port data is discarded UDP Point to Point In this configuration the TDD COFDM will send serial data to a specifically defined point using UDP packets This same TDD COFDM will accept UDP packets from that ...

Страница 12: ...ss you should correct another device s Remote IP Addr into the same IP SET or the serial port will lose connection For example you have changed the master s IP address to 192 168 55 5 the you should correct the salver s Remote IP Addr to 192 168 55 5 7 RF New NET Configuration method 7 1 RF Net ID Each network of TDD COFDM modules must have a unique Network ID This Network ID must be set in each u...

Отзывы: