background image

 

 

Doc. Title

 

Author

 

 

 

Page of Pages

 

ST4300 OPERATION MANUAL  

SE PARK 

 

 

1 of 13 

Concerning

 

Doc. No.

 

Rev.

 

Date

 

Features and How to set parameters 

 

1.01 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27 NOV 2016 

 

Suntech International Ltd. 

 

Confidential Document 

 

 

 

Operation Manual 

 

 

 

 

 

ST4300 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suntech International Ltd. 

 

 

 

 

 

 

 

CONFIDENTIAL DOCUMENT

 

This document belongs to intellectual property of Suntech 

International Ltd. and shall neither be copied nor be given to any 

3rd parties without prior written consent from the company. 

DO NOT MAKE ANY COPIES 

 

Содержание ST4300

Страница 1: ...27 NOV 2016 Suntech International Ltd Confidential Document Operation Manual ST4300 Suntech International Ltd CONFIDENTIAL DOCUMENT This document belongs to intellectual property of Suntech Internatio...

Страница 2: ...ameter change 5 2 4 Features 5 3 Detailed Description on Event Lines and Features 7 3 1 Total 14 pin Event Lines 7 3 2 Immobilizer 7 3 3 Alert of Buzzer 8 3 3 1 Related with over speed 8 3 4 Indicatio...

Страница 3: ...ntinuously from time to time by Suntech any alteration on the protocol the firmware functions the hardware specifications of the product is subject to change without prior notice Copyright We at Sunte...

Страница 4: ...tion including installation in addition to the Device Manual users should refer to other documents such as Parameter Manual Commands Manual Reporting Manual and so on 2 Overview Main function of devic...

Страница 5: ...in the report so that they can configure their own report format Multiple Modes Customer can set up multiple modes of operation so they can see more detailed routes as needed Each operation mode consi...

Страница 6: ...ce i e vehicle s battery and is able to inform the server about status on whether or not the main power line is disconnected The device is also able to inform the server about the voltage level status...

Страница 7: ...for collecting information from and delivering command to the vehicle It has 14 wires among which 3 wires are for Vcc GND and Ignition and the other 11 wires are for inputs outputs audio and RS232 3...

Страница 8: ...buzzer alerts The following table shows such cases 3 3 1 Related with over speed Condition Alert Pulse Meaning Over speed Out Buzzer When vehicle s speed exceeds the over speed value 3 4 Indication wi...

Страница 9: ...et of GPRS HSPA antenna is broken 3 If the device is broken SIM PIN Locked 5 Probable Situation 1 If SIM PIN is enabled Cannot Attach NW 6 Probable Situations 1 If device receives weak GPRS HSPA signa...

Страница 10: ...nd GPRS HSPA part For the time of Sleep all communication with the server is impossible and it cannot receive any SMS messages either Device turns on GPRS HSPA session every max 30 minutes However the...

Страница 11: ...ill be disabled for a while for 30 seconds so as to avoid sending to the server the same message as the first one repeatedly About Threshold Collision Threshold Our recommendation is 0 7 but it is onl...

Страница 12: ...hanged by making a Command Refer to Voltage control parameters section 3 9 Storage of Reports un sent Device has maximum storage capacity of the un sent reports in such cases as follows 2 000 reports...

Страница 13: ...ng the TAG ID is transmitted to the server Please refer to the 4 13 and 6 4 chapter 3 12 Temperature Sensor Our device supports up to 8 temperature sensors Each temperature sensor has its own number i...

Отзывы: