23
slightly to release the cover. The particle screen (pre-filter) is the dark grey material
located directly against the intake cover grill. Remove the particle screen (pre-filter)
and rinse with clean, warm tap water. Do not use detergent or cleaning solutions.
Gently squeeze out excess moisture but do NOT twist or “wring out” the material.
Allow the particle screen to dry fully before placing it back inside the unit.
3. To replace the unit’s dual multi-function cartridges, you will need to remove the air
intake cover as described above. You will see one cartridge inside the unit. If the
cartridges colour appears similar to the indicator below, this indicates replacements
are needed. When replacing these, you will need to slide the cartridge completely
“up”. Please make sure that the white “pleated” sides of the cartridge face out toward
the intake cover grill.
Multi-function cartridge replacement indicator:
(compare only to the pleated side of the cartridge)
OK ………………. REPLACE
Safe operation
The healthy air cleaner is made using the finest electronic parts and high quality
components. Always observe standard safety guidelines when using your purifier.
1. Only operate the unit in a safe, dry environment.
2. Never open, move, or attempt to clean the unit while operating. Always unplug the
unit before doing so.
3. Do not insert objects through the grill openings.
4. Never attempt to modify, disassemble or repair the unit yourself.
5. Do not operate the unit near or around water or damp areas to reduce the risk of
electric shock. Similarly, do not handle the unit with wet hands.
6. Do not operate or place the machine near flammable materials, liquids, or gases
of any kind.
7. Keep away from children and always supervise the unit when in use.
8. To reduce the risk of personal injury, shock, or fire, do not use an extension cord.
Carefully examine the unit’s cord before use to make sure it is not damaged and it
is intact. Do not use the unit if otherwise.
9. Do not use the unit if any of its parts may be damaged or missing.
10. This unit is intended for normal indoor residential use only.
11. Never immerse the unit in water or use solvents to clean.
12. If you or anyone in your household may have a sensitivity to very low ozone
(<0,04ppm), consult with your physician before using this or any similar device.
Small amounts of ozone are helpful for bacteria and germ control.
13. Always ensure that both the air intake and air outlet are never obstructed. Do not
allow objects to block either opening.
14. This machine is not a medical device and is not intended as a treatment for any
medical condition.
15. Check the unit often and clean as needed to prevent dirt accumulation which
might otherwise reduce efficiency or pose fire risk.
16. Do not attempt to operate a malfunctioning unit. If it is safe to do so, unplug it
immediately.