4.14. Program Charge / Discharge Times Page
To program charge and discharge times click on the “System Mode” icon after clicking on the gear icon.
Concerning the detailed figure above:
1.
Tick this box to do not export power back to the grid (the CT coil will detect power flowing back to the
grid and will reduce the power of the inverter only to supply the local load).
2.
Tick this box if you wish to export your solar power back to the grid.
3.
Tick this box if you only want to supply power to the load side of the inverter.
4.
Zero export power is the amount of power flowing from the grid to the inverter. Set this value to 20
–
100W to force the inverter to always take this amount of power from the grid to minimise nuisance
“Reverse Power Detection” tripping of sensitive prepaid electricity meters.
5.
This controls the maximum overall power, both to the load and grid ports combined. It is set to low if
an over current fault occurs.
What this page displays:
Prevent export power to the grid with "Zero
Export".
Limit power to supply to only all the house
loads with "Solar Export".
Limit power to supply only the loads
connected to LOAD port with "Limit to Load
only".
What you can do from this page:
Define a real time to charge or discharge the
battery.
Choose to charge the battery from the grid
or generator.
Limit export power to the grid.
Define to
charge
the battery from the grid or
generator ticking Grid or Gen and define
when it needs to occur.
Define the time to
discharge
to the load or
export to the grid by unticking Grid and Gen.