40
22) Adjusting the pneumatic pressure
A. As in the figure, pull down the adjusting knobs
①
at the
bottom of the filter regulator attached under the table and
turn them to the right. Then pressure increases. When they
are turned to the other side, pressure decreases. When
pressure indicated on the pressure gauge is properly
adjusted, place the adjusting knobs
①
back to their original
position and fix them.
B. The proper pressure of the main adjuster
②
sis 0.5MPa, and
that of the cutter adjuster
③
is 0.3MPa.
[ Fig. 58 ]
②
①
③
[ Fig. 57 ]
②
①
③
before sewing:
3.6mm
after sewing:
5.0mm
21) Adjusting the fabric opening
A. The fabric opening should be 1.4mm composed of 0.7mm
of the left plate opening
①
and 0.7mm of the right plate
opening
②
respectively.
B. Loosen the tightening screw
③
for the fabric opening
cylinder and set the distance between the left cover plate
①
and the right cover plate
②
at 3.6mm.
C. During the operation of the fabric opening cylinder, adjust
the cover plate cushion position to set the distance between
cover plates at 5.0mm. In this case, the opening of the left
and right cover plates should be same.