XTT 5000 User's Manual
Select RFC2544/NE Test as the test type on the
to perform RFC-2544 tests.
Use the '
l' (
) button to set a loop if necessary.
Left Column - Test Basics
Type
: Determine the type of RFC2544 test to perform.
•
An
RFC2544
test tests a device by transmitting various frame lengths at
different rates to find the maximum throughput rate.
•
An
NE
test stresses a NE at a variety of rates, which you define.
Run Continuously
: N/A. The RFC2544 test will run continuously when this is set to
On.
•
Once the test sequence is completed, the module will run the sequence again
without saving the test results. This allows RFC2544 to be used as a long
term test.
Estimated Test Time
: View an estimation of how long it will take to run theselected
tests, in a days, hours, minutes format.54qaz\`z`QRFTG12Choose the Tests to Run
To select a throughput or NE test to run
, press its button to turn it On. The
Estimated Test Time reflects the predicted test run time for the tests selected.
•
You may run several tests in sequence.
Trial
Description
Set at On, the RFC2544 Trial Description runs before the main
test starts. If it fails, no further testing occurs.
Throughput
This test uses a binary search to determine the maximum traffic
rate (expressed as a percentage) the DUT can pass without
losing any frames.
Latency
Determines the round trip delay of the frame through the DUT.
Latency Mode
:
•
Standard
follows the guidelines of RFC 2544, which
can take several hours for a complete test.
•
Quick
measures the round trip delay while it is
performing the Throughput test and takes no extra
time. Results from failed throughput tests are
discarded, and only the results from the highest
successful throughput test are kept and recorded.
Frame Loss
Generates a table that shows the percentage of lost frames as a
function of frame rate, expressed as a percentage.
Back to
Back
Determines the maximum number of frames sent back to- back
at 100% frame rate that the DUT can process without losing
frames
DUT Type
Select the type of far end device under test: ROUTER or
BRIDGE.
Multi-Port
View or set the port connections. RFC-2544 tests require the use of two ports. RFC
2544 may be run between two different ports such as:
XFP - SFP
XFP - RJ-45
SFP - SFP
SFP - RJ-45
90
Содержание XTT 5000
Страница 1: ...XTT 5000 User s Manual...
Страница 2: ......
Страница 6: ......
Страница 11: ...XTT 5000 System Monitor Applications Monitor Setup Technology Overview Learn about Ethernet technology 5...
Страница 36: ......
Страница 52: ...XTT 5000 User s Manual L1 BERT Diagram Home Layer 1 BERT Applications Where do you want to go next Home 46...
Страница 55: ...Throughput Testing L2 BERT Diagram Home Layer 2 BERT Where do you want to go next Home 49...
Страница 58: ...XTT 5000 User s Manual Throughput Stream Results Throughput Test Setup Working Desktop Home 52...
Страница 61: ...Throughput Testing Home 55...
Страница 67: ...Throughput Testing Throughput Aggregate Results Throughput Stream Results Home 61...
Страница 81: ...Throughput Testing Working Desktop Home 75...
Страница 83: ...Throughput Testing Home 77...
Страница 106: ...XTT 5000 User s Manual Throughput Stream Results Throughput Test Setup Working Desktop Home 100...
Страница 116: ......
Страница 142: ......
Страница 147: ...Save Features 141 RFC2544 NE Applications IP Test Setup Monitor Setup Loopback Test Setup Home...
Страница 148: ......
Страница 172: ......
Страница 181: ...Index 175 X XFP 40 XFP Port Setup 40...