Sunny Emergency Exit Series Скачать руководство пользователя страница 1

1. Having LED lifetime of over 50,000 hours.

2. The sign is made with clear acrylic sheet that evenly diffuse the lightthroughout 
    the whole sign, even after an extended period of use.

3. Automatically recharged with constant voltage and limited current.
4.The High Temperature type Ni-MH (Nikle Metal Hydride) batteries are suited for
    emergency exit signs that are installed in areas with high temperature such as 

    above ceiling spaces, walkways, fire escapes and other areas.

5. Support long distance testing using the infrared remote (Only Series 4 or 

    Special Order).

LED 

AC.

LED 

Full

LED 

Charge

Switch 

ON

Switch 

TEST

Switch 

OFF

Indicating input status.

Indicating the battery is fully charged.

Indicating charging status.

For turning on device (not plugged in).

For truning off the device (not plugged in).

For testing device availability
(during normal circumstance).

Slim Line Series Type R 

Slim Line Series Type C,W 

Box Series 

USER MANUAL

Emergency Exit Sign Light 

Features

Status Indicators and Testing Buttons

Содержание Emergency Exit Series

Страница 1: ...ture such as above ceiling spaces walkways fire escapes and other areas 5 Support long distance testing using the infrared remote Only Series 4 or Special Order LED AC LED Full LED Charge Switch ON Switch TEST Switch OFF Indicating input status Indicating the battery is fully charged Indicating charging status For turning on device not plugged in For truning off the device not plugged in For testin...

Страница 2: ...power supply 5 Check the CHARGE or FULL LED light to see the status of the battery The CHARGE LED will be on when the battery is charging and the FULL LED will be on when the battery is fully charged 6 Check if the TEST switch is working When pressed the sign should illuminate and the AC LED should turn off 7 The ON and OFF switches are used to turn the sign on and off when the emergency exit sign...

Страница 3: ... loose from its socket The unit s battery is not fully charged The unit s battery might have expired and need to be replaced Check that the power socket is providing 220 Volts AC power Inspect the 220 Volts AC Fuse Inspect the units electrical plug Replace the DC fuse Charge the unit s battery for 10 15 hours Contact our service department for battery replacement Surface Ceiling Mounted Surface Wa...

Страница 4: ...specified within the manual The unit has been damaged from impact for example parts are dented scratched missing or distorted The unit has been modified or repaired by people not officially certified by our company The Sticker Warranty Void has been removed or torn The unit is damaged from negligence or incompetent use for example the battery is swollen the batter has been overcharged the battery has...

Отзывы: