iii) The following Dialog will be displayed. Press [Finish].
Multifunctional Flash Microcomputer [S550-MFW1U]
45
Operation Manual
Страница 1: ...Multifunctional Flash Microcomputer Programmer S550 MFW1U Operation Manual Sunny Giken Inc ...
Страница 2: ...ed to this product claimed by users and or any intermediaries Specifications of this product and or the software attached to this product may be modified without notice for improvement The names of systems products and or services used in this manual are either registered trademarks or trademarks of each manufacturer The captions of the TM and R are not mentioned in this manual Multifunctional Fla...
Страница 3: ...n Specifications for Serial Programming 18 5 1 Connector MFW1U Unit 18 5 2 Pin Assignment MFW1U Unit 18 5 3 Serial Programming Cable 19 5 4 Connection Circuit Example for the MFW1U 20 6 Updating Firmware 38 7 MFW1U Standalone Operation 39 7 1 Standalone Programming to Parallel Adapter 39 7 2 Standalone Programming to Serial Adapter 40 7 3 Standalone Programming to User Target Board 40 7 4 Initiali...
Страница 4: ...this product apart and or modify by yourself 2 Use Environment Unusable environment Dusty place Place in the presence of corrosive gasses Place exposed to direct sunlight Place surrounded by equipment which originates noises Place with severe mechanical shock and or constant mechanical vibration Ambient temperature 0 C to 40 C Humidity below 80 non condensing Prevention of electrostatic buildup fo...
Страница 5: ...t MFW1U unit Parallel adapter Up to 8 adapters can be attached Gang prgramming Cable for serial programming hereinafter called the serialcable Target board or connector at the serial adapter side should be prepare by user Serial adapter Target board Prepared by user DC Cable for Oversea The AC adapter is not attached for the export product Refer to the 4 Setting Up for detailed and varied connecti...
Страница 6: ...sea standards FCC compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Parallel Adapter Outer dimensions 162 W x 53 D x 16 H mm Projection not included Weight Less than 400g B...
Страница 7: ...rial I O applicable to R8C Family Clock asynchronous serial I O mode not supported PC parallel programming PC serial programming PC onboard programming Standalone parallel programming Standalone serial programming Program Mode Standalone onboard programming Program data Size Max 1Mbyte PC control Software All the operation can be achieved from your PC with easy to operate GUI graphic user interfac...
Страница 8: ...uter M16C Family are programmable by the MFW1U Some of devices are still under evaluation or not programmable Refer to the file Programmable Device List in an attachment floppy disk Contact Sunny Giken Inc for the latest information Multifunctional Flash Microcomputer S550 MFW1U 7 Operation Manual ...
Страница 9: ...ART switch more than 5 seconds PARALLEL SOCKET Turns it ON when programming target is parallel adapter with definition by PC SERIAL SOCKET Turns it ON when programming target is serial adapter with definition by PC SERIAL TARGET Turns it ON when programming target is user target board with definition by PC PASS Turns it ON when serial programming is successful ID ERR Turns it ON when result of ser...
Страница 10: ...communication connector connected to PC Left hand side view SERIAL Connector Function SERIAL Serial programming connector for target board or serial adapter Right hand side view PARALLEL Connector Function PARALLEL Parallel programming connector for parallel adapter Multifunctional Flash Microcomputer S550 MFW1U 9 Operation Manual ...
Страница 11: ...ector 1 Parallel programming connector from the MFW1U Connector 2 Gang parallel programming connector when more than one parallel adapters attached The shape of the IC socket of the parallel adapter is varied from to be attached device type Refer to separate Programmable Device List for your order Up to 8 parallel adapters can be connected and programmed at once gang programming But to be gang pro...
Страница 12: ...vice mounter socket side is acceptable but securing also at the topside is reliable and recommended The attachment figure is shown below M2 6 Screw Latch es at the top side Latch es at mounter socket side Unscrew the M2 6 screws that hold a case cover and screw and attach adapters by referring the above illustration Screwing to the MFW1U unit is not applicable Multifunctional Flash Microcomputer S...
Страница 13: ... to 8 adapters can be attached Gang prgramming Parallel adapter 1 Parallel adapter 2 Parallel adapter 8 DC Cable for Oversea Up to 8 parallel adapters can be connected and programmed at once gang programming Devices to be gang programmed should be the same type in order to avoid breakage of the devices Beware that the power of the MFW1U is OFF when attaching parallel adapter s Multifunctional Flas...
Страница 14: ...by user Serial adapter DC Cable for Oversea Power supply to the serial adapter for serial programming is provided by the MFW1U via Vcc pins Particular power supply is not required A serial adapter can be prepared by obtaining the IC socket type programming board made by Renesas Electronics Some modification to the board is needed since the board mounts Vcc3 3V 5V switch circuit Please contact Sunn...
Страница 15: ... Windows98 Me 2000 XP 7 32bit 64bit Serial cable Connector at the serial adapter side shuold be prepared by user DC Cable for Oversea Power supply to the MFW1U for serial programming to a user target board is provided by a user target board via Vcc pins Attach the AC adapter to supply power when the current capacity of the target board is insufficient since the maximum current consumption of the M...
Страница 16: ... PC to the MFW1U such as lock bit data and several settings retains at the MFW1U even if the power switch is turned OFF Simple operation for everyone without a complicated setting to PC is available by selecting Up to 8 parallel adapters can be connected and programmed at once gang programming Devices to be gang programmed should be the same type in order to avoid breakage of devices Beware that t...
Страница 17: ...ailable by selecting Power supply to the serial adapter for serial programming is provided by the MFW1U via Vcc pins Particular power supply is not required A serial adapter can be prepared by obtaining the IC socket type programming board made by Renesas Electronics Some modification to the board is needed since the board mounts Vcc3 3V 5V switch circuit Please contact Sunny Giken Inc before oper...
Страница 18: ...itch is turned OFF Simple operation for everyone without a complicated setting to PC is available by selecting Power supply of the MFW1U for serial programming is provided by a user target board via Vcc pins Attach the AC adapter to supply power when the current capacity of the target board is insufficient since the maximum current consumption of the MFW1U for serial programming is 200mA All the s...
Страница 19: ...rogramming Input 3 CLK Clock signal output for serial programming Output 4 TXD Transmission data for serial programming Output 5 CE CE signal output for serial programming Output 6 EPM EPM signal output for serial programming Output 7 GND Signal ground 8 RESET RESET signal output for serial programming Output 9 CNVss CNVss Vpp signal output for serial programming Output 10 RXD Receiving data for s...
Страница 20: ...ing cable should be less than 500mm Be sure to arrange the total length between cable and the target CPU is less than 500mm even if the length of a serial cable is less than 500mm The following figure shows the cable polarity 500mm 1Pin Connector Model HIF3BA 10D 2 54R Manufactured by Hirose Electrics As for serial I O mode of M16C 20 and M16C 21 Group an exclusive programming connector MFW 20SP i...
Страница 21: ...d to the Vcc terminal directory Attach the AC adapter to supply power when the current capacity of the target board is insufficient since the maximum current consumption of the MFW1U for serial programming is 200mA Usage of Vcc should be 3 3V 5 or 5V 5 Note 2 Isolate TXD RXD SCLK and or BUSY terminals from the MCU peripheral circuit by jumper analog switch three state etc when serial programming i...
Страница 22: ...nect the reset terminal of the user target board MCU to the RESET terminal of the MFW1U directly when the reset circuit of the user target board is open collector output CR delay circuit or constant current load circuit is less than dozens of μA Execute the same procedure as Note 2 when it is CMOS output Note 6 The Vss terminal should be connected since it is signal ground Please combine with this...
Страница 23: ... when the current capacity of the target board is insufficient since the maximum current consumption of the MFW1U for serial programming is 200mA Usage of Vcc should be 3 3V 5 or 5V 5 Note 4 Isolate TXD RXD SCLK and or BUSY terminals from the MCU peripheral circuit by jumper analog switch three state etc when serial programming is achieved Isolation can be omitted when those signal statuses are ou...
Страница 24: ...terminal of the MFW1U directly when the reset circuit of the user target board is open collector output CR delay circuit or constant current load circuit is less than dozens of μA Execute the same procedure as Note 2 when it is CMOS output Note 8 The Vss terminal should be connected since it is signal ground Please combine with this example of a connection circuit and confirm a Hardware manual or ...
Страница 25: ... programming is achieved Isolation can be omitted when those signal statuses are output from the MCU peripheral circuit Resistance should be 4 7KΩ or over when pull up is achieved to these signals Note 3 Connect the MCU CNVss terminal to Vss of the user target board but do not connect to the CNVss terminal of the MFW1U unit Note 4 Connect the MCU BUSY terminal to the BUSY terminal of the MFW1U uni...
Страница 26: ...log switch three state etc when serial I O programming is achieved Isolation can be omitted when those signal statuses are output from the MCU peripheral circuit Resistance should be 4 7KΩ or over when pull up is achieved to these signals Note 3 Connect the MCU CNVss terminal to the CNVss terminal of the MFW1U unit by achieving pull down with resistance of 4 7KΩ Note 4 Connect the reset terminal o...
Страница 27: ...eved to these signals Note 3 Execute the same procedure as Note 2 for CE terminal Or only isolation process by achieving pull up without the MFW1U connection is also applicable On board direct fix is also available of the CE terminal for H level when these terminals are not connected Note 4 Execute the same procedure as Note 2 for SEL terminal Or only isolation process by achieving pull down witho...
Страница 28: ... be connected since it is signal ground Please combine with this example of a connection circuit and confirm a Hardware manual or a Data sheet of each microcomputer Multifunctional Flash Microcomputer S550 MFW1U 27 Operation Manual ...
Страница 29: ... I O programming is achieved Isolation can be omitted when those signal statuses are output from the MCU peripheral circuit Resistance should be 4 7KΩ or over when pull up is achieved to these signals Note 3 Connect the MCU CNVss terminal to the CNVss terminal of the MFW1U unit by achieving pull down with resistance of 4 7KΩ Note 4 Connect the reset terminal of the user target board MCU to the RES...
Страница 30: ...ut from the MCU peripheral circuit Resistance should be 4 7KΩ or over when pull up is achieved to these signals Note 3 Execute the same procedure as Note 2 for CE terminal Or only isolation process by achieving pull up without the MFW1U connection is also applicable On board direct fix is also available of the CE terminal for H level when these terminals are not connected Note 4 Connect the MCU CN...
Страница 31: ... 7KΩ or over when pull up is achieved to these signals Note 3 Execute the same procedure as Note 2 for CE and RP terminal Connect CE terminal to CE of MFW1U or connect RP terminal to EPM of MFW1U Or only isolation process by achieving pull up down without the MFW1U connection is also applicable On board direct fix is also available of the CE terminal for H level or the RP terminal for L level when...
Страница 32: ...s achieved to these signals Note 3 Execute the same procedure as Note 2 for CE P16 and RP terminal Connect CE terminal to CE of MFW1U or connect P16 terminal to CE of MFW1U and connect RP terminal to EPM of MFW1U Or only isolation process by achieving pull up down without the MFW1U connection is also applicable On board direct fix is also available of the CE terminal for H level or the P16 termina...
Страница 33: ...rial I O programming is achieved Isolation can be omitted when those signal statuses are output from the MCU peripheral circuit Resistance should be 4 7KΩ or over when pull up is achieved to these signals Note 3 Connect the MCU CNVss terminal to the CNVss terminal of the MFW1U unit by achieving pull down with resistance of 4 7KΩ Note 4 Connect the reset terminal of the user target board MCU to the...
Страница 34: ...e MCU peripheral circuit Resistance should be 4 7KΩ or over when pull up is achieved to these signals Note 3 Connect the MCU MODE terminal to the BUSY terminal of the MFW1U unit by achieving pull up with resistance of 4 7KΩ Note 4 Connect the MCU CNVss terminal to the CLK terminal of the MFW1U unit by achieving pull down with resistance of 4 7KΩ Note 5 Connect the reset terminal of the user target...
Страница 35: ...l to the CLK terminal of the MFW1U unit by achieving pull up with resistance of 4 7KΩ Note 3 Connect the reset terminal of the user target board MCU to the RESET terminal of the MFW1U directly when the reset circuit of the user target board is open collector output CR delay circuit or constant current load circuit is less than dozens of μA Isolate TXD RXD and or BUSY terminals from the MCU periphe...
Страница 36: ...5 or 5V 5 Note 2 Connect the MCU MODE terminal to the CLK terminal of the MFW1U unit by achieving pull up with resistance of 4 7KΩ Note 3 Connect the reset terminal of the user target board MCU to the RESET terminal of the MFW1U directly when the reset circuit of the user target board is open collector output CR delay circuit or constant current load circuit is less than dozens of μA Isolate TXD R...
Страница 37: ...ould be 4 7KΩ or over when pull up is achieved to these signals Note 3 Execute the same procedure as Note 2 for CE terminal Or only isolation process by achieving pull up without the MFW1U connection is also applicable On board direct fix is also available of the CE terminal for H level when these terminals are not connected Note 4 Connect the MCU CNVss terminal to the CNVss terminal of the MFW1U ...
Страница 38: ...by achieving pull up with resistance of 10KΩ Note 4 In the serial write mode connect CNVss termial of MFW1U and disconnect Vss termial from the MCU by jumper switch In the normal Microcomputer mode disconnect CNVss termial of MFW1U and connect Vss termial from the MCU by jumper switch Note 5 Connect the reset terminal of the user target board MCU to the RESET terminal of the MFW1U directly when th...
Страница 39: ...of MFW will achieve waiting state for updating firmware Then update the firmware from the control program of the MFW Control Software For more information on updating firmware please refer to the MFW Control Software Operation Manual Multifunctional Flash Microcomputer S550 MFW1U 38 Operation Manual ...
Страница 40: ...from the control program 3 Place a target device onto the mounter socket of the adapter 4 Press the START switch to execute the selected action at the main programming screen Result of Action execution is output at the PASS FAIL LEDs of the adapter Both of the PASS FAIL LEDs are on when a contact error is occurred during execution and operation is interrupted 1 Achieve procedure 3 4 repeatedly for...
Страница 41: ...r target board to the MFW1U unit Not connect a USB cable 2 Turn ON the power of the user target board Make sure the power of the MFW1U is off 2 Make sure the SERIAL TARGET LED is on All the LEDs are off when device type and data are not loaded to the MFW1U unit from the control program 3 Press the START switch to execute the selected action at the main programming screen 3 4 Result of Action execu...
Страница 42: ... the MFW1U unit Attachment of a parallel adapter serial adapter or user target board is not necessary Achievement is also available when attached 2 Press the START switch for 5 seconds to start initialization A series of short beeps P P P is issued when initialization is started and a short beep Peep is issued when finished then all the LEDs are turned off Multifunctional Flash Microcomputer S550 ...
Страница 43: ...ASS is on When failing FAIL is on Programming by serial adapter LEDs of MFW1U When ID error is occurred ID ERR is on malfunction of device may be considered When internal memory is damaged N A MFW1U malfunction LEDs of MFW1U Troubled during initialization right after power is on N A 7 6 List of Beep Sounds Action Beep Sounds When power is on a long beep sound Peep When start switch is on a short b...
Страница 44: ... causes are considered for a contact error Release the probable error causes and retry the operation 1 The device is placed improperly such as up side down wrong side or deviation 2 Fail to make connection is occurred since the pin of the IC socket or device is bent 3 Defective of the device Note that the following exceptions are examined 1 Fail to make connection of the Vcc pin Both of the PASS F...
Страница 45: ...Execute dpinst exe of the Driver32 folder Device Driver Installation Wizard Dialog will be displayed Press Next ii The USB driver package is being installed Please wait for a moment Multifunctional Flash Microcomputer S550 MFW1U 44 Operation Manual ...
Страница 46: ...iii The following Dialog will be displayed Press Finish Multifunctional Flash Microcomputer S550 MFW1U 45 Operation Manual ...
Страница 47: ...te dpinst exe of the Driver64 folder Device Driver Installation Wizard Dialog will be displayed Press Next ii The following Dialog will be displayed Press Install Multifunctional Flash Microcomputer S550 MFW1U 46 Operation Manual ...
Страница 48: ...ⅲ The USB driver package is being installed Please wait for a moment ⅳ The following Dialog will be displayed Press Finish Multifunctional Flash Microcomputer S550 MFW1U 47 Operation Manual ...
Страница 49: ...w hardware and creates driver information database The procedure for installing USB Driver is described below i Add New Hardware Wizard Dialog will be displayed Press Next ii Select Search for a suitable driver for your device recommended and press Next Multifunctional Flash Microcomputer S550 MFW1U 48 Operation Manual ...
Страница 50: ...iii Select Specify a location and press Next iv Specify USBDrv folder in the attached CD ROM for areas to be inspected Multifunctional Flash Microcomputer S550 MFW1U 49 Operation Manual ...
Страница 51: ...v S550 MFW1U will be viewed Press Next vi The driver files will be automatically copied and then installation will be completed Multifunctional Flash Microcomputer S550 MFW1U 50 Operation Manual ...
Страница 52: ...A6 5 4 The S550 MFW1U connection circuit example for 7542 has been changed Jun 07 2004 Rev B 5 4 The S550 MFW1U connection circuit example for R8C 14 R8C 15 R8C 16 and R8C 17 has been added Sep 03 2004 Rev B1 5 4 The S550 MFW1U connection circuit example for 7542 has been changed Dec 10 2004 Rev B2 5 4 The S550 MFW1U connection circuit example for M16C 28 and M16C 29 has been changed Apr 20 2005 R...
Страница 53: ... R8C LX has been added Jul 27 2009 Rev H 5 4 The resistance of the CNVss terminal in the S550 MFW1U connection circuit example is corrected from 10KΩ to 4 7KΩ or more 1 2 4 5 6 7 8 9 10 11 14 5 4 The resistance of the MODE terminal in the S550 MFW1U connection circuit example is corrected from 10KΩ to 4 7KΩ or more 11 5 4 The resistance of the MODE terminal in the S550 MFW1U connection circuit exa...
Страница 54: ...device must accept any interference received including interference that may cause undesired operation Multifunctional Flash Microcomputer Programmer S550 MFW1U Operation Manual Date of Issue Apr 2003 The First Edition Jul 2011 Rev J Editor SUNNY GIKEN INC Published by SUNNY GIKEN INC 3 1 9 Nishidai Itami Hyogo JAPAN 664 0858 E mail info sunnygiken co jp 2003 2011 Sunny Giken Inc All rights reserv...