Risk of explosion and fire.
Caution: Metal parts of the battery are
always under voltage. Do not place tools
or other metal objects on the battery
!
Avoid short circuits
!
Electrolyte is highly corrosive.
Batteries and cells are heavy.
Ensure secure installation
!
Use only suitable handling equipment e.g.
lifting gear in accordance with VDI 3616.
Dangerous voltage
!
Batteries with this symbol can be recycled.
Treat batteries as special waste.
Do not mix them with other industrial
or household waste. Recycling can be
achieved through a recognized company
for battery recycling or by returning them
to the manufacturer, depending on the
agreement you have made.
Instructions for Use
Motive Power (Traction) Batteries with Positive Tubular Plates
PzS and PzB, HydroSave Batteries
Read the instructions carefully and place
them close to the battery.
Work on batteries to be carried out by
skilled personnel only
!
Disregarding the operation instructions, repair with non-original parts or using additives for the electrolyte will render
the warranty void.
Use protective glasses, protective gloves
and apron when working on batteries.
Pay attention to the accident prevention
rules as well as EN 50272-3 and
EN 50110-1.
No smoking
!
Do not expose batteries to naked flames,
glowing embers or sparks, as it may
cause an explosion.
Do not expose batteries to naked flames,
glowing embers or sparks, as it may
cause an explosion.
Clothing contaminated by acid should be
washed in water.
Safety Instructions
1. Nominal capacity C
5
: See battery label
2. Nominal voltage : 2.0 V x number of cells
3. Discharge current : C
5
/5h
4. Final discharge voltage : 1.7 V x number of cells
Rating Data
5. Nominal electrolyte density*: 1.29 g/ml at 30°C
6. Rated temperature : 30°C
7. Nominal electrolyte level : upper step of plug**
* will be reached within the first 10 cycles
** see picture in point 3.1
www.systems-sunlight.com