Sunlight HydroSave PzS Series Скачать руководство пользователя страница 1

Risk of explosion and fire. 
Caution: Metal parts of the battery are 
always under voltage. Do not place tools
or other metal objects on the battery

!

Avoid short circuits

!

Electrolyte is highly corrosive.

Batteries and cells are heavy.
Ensure secure installation

!

Use only suitable handling equipment e.g.
lifting gear in accordance with VDI 3616.

Dangerous voltage

!

Batteries with this symbol can be recycled.

Treat batteries as special waste. 
Do not mix them with other industrial 
or household waste. Recycling can be
achieved through a recognized company
for battery recycling or by returning them
to the manufacturer, depending on the
agreement you have made.

Instructions for Use

Motive Power (Traction) Batteries with Positive Tubular Plates

PzS and PzB, HydroSave Batteries

Read the instructions carefully and place
them close to the battery.

Work on batteries to be carried out by
skilled personnel only

!

Disregarding the operation instructions, repair with non-original parts or using additives for the electrolyte will render
the warranty void.

Use protective glasses, protective gloves
and apron when working on batteries.
Pay attention to the accident prevention
rules as well as EN 50272-3 and 
EN 50110-1. 

No smoking

!

Do not expose batteries to naked flames,
glowing embers or sparks, as it may
cause an explosion.

Do not expose batteries to naked flames,
glowing embers or sparks, as it may
cause an explosion.

Clothing contaminated by acid should be
washed in water.

Safety Instructions

1. Nominal capacity C

5

              : See battery label

2. Nominal voltage                     : 2.0 V x number of cells 

3. Discharge current                  : C

5

/5h 

4. Final discharge voltage         : 1.7 V x number of cells 

Rating Data

5. Nominal electrolyte density*: 1.29 g/ml at 30°C 

6. Rated temperature                : 30°C 

7. Nominal electrolyte level       : upper step of plug**

* will be reached within the first 10 cycles
** see picture in point 3.1

www.systems-sunlight.com

Содержание HydroSave PzS Series

Страница 1: ...tery Work on batteries to be carried out by skilled personnel only Disregarding the operation instructions repair with non original parts or using additives for the electrolyte will render the warranty void Use protective glasses protective gloves and apron when working on batteries Pay attention to the accident prevention rules as well as EN 50272 3 and EN 50110 1 No smoking Do not expose batteri...

Страница 2: ...n closed With the charger switched off connect up the battery ensuring that the polarity is correct positive to positive negative to negative Then switch on the charger When charging the temperature of the electrolyte rises by about 10 C so charging should only begin if the electrolyte tem perature is below 45 C The electrolyte temperature of batteries should be at least 10 C before charging other...

Страница 3: ...lve allows the flow of water into each cell and the float seals the valve when the correct electrolyte level has been reached The filling plug shows a white dot if the float has sealed the valve The electrolyte density may be measured by opening the plug cover and inserting the hydrometer probe through the plug s relevant opening For a fault free operation of the water refilling system please cons...

Страница 4: ... used the battery should only be connected to the water supply once per week to avoid overfilling If the charger incorporates a watering function the quick couplings of the battery and the charger are connected before charging and the water flow is controlled by the charger s PCB board which operates an electromagnetic valve 8 4 Filling Time The filling time depends on the battery s usage and its ...

Отзывы: