Mystic Tan Kyss™
Owner’s Manual
47
404
Session cancelled with liquid remaining in
reservoir- (current reservoir level)
Displays the current volume in reservoir (scale of 1-19)
after a session was manually cancelled. Ignores values 2
or below.
•
Purge solution out before inserting new
cartridge
•
Or run another session to empty reservoir
405
Low air pressure (below 17.5 psi)
Air pressure drops below the minimum level, can affect
performance. See section T5 for help.
406
High air pressure (above 22.5 psi)
Air pressure above maximum level, can affect
performance. See section T5 for help.
407
Session cancelled manually
Shows that a session was manually canceled by user.
408
Session stopped - acknowledgment not
received from MTDC board
Internal communication error. No communication
before timeout. Returns to Home screen.
409
Reservoir overfilled- (current reservoir
level)
Reservoir volume exceeds level 14. Do not add more
solution. Purge to reduce volume if value is 18+.
410
Liquid remaining in reservoir BEFORE
purge- (current reservoir level)
Displays current volume in reservoir before a purge on a
scale of 1-19. Ignores values of 2 or below.
Red Faults
Fault
Code
Display Message
Description
101
Vertical motor home switch not detected
Vertical motor not finding the home position sensor.
Session will be canceled.
•
Go to Technical/Diagnostic Outputs and turn
Vertical Motor On
•
If the motor is running, is the nozzle moving up
and down?
•
If the nozzle is not moving up and down, check
vertical motor set screw
•
If the nozzle is moving up and down, watch the
screen where is says Home Switch
•
If you see it turn from Not Home to Home,
monitor situation home switch is working
•
If it does not turn from Not Home to Home,
check vertical motor cam arm set screw, may
be loose.
102
Vertical motor current over maximum mA
during enable
Session cancelled to avoid overcurrent to vertical motor.
•
Motor is struggling to move
•
Check for obstructions creating drag on the
motor
•
Check voltage (24V DC)
•
If voltage is good and no obstructions, replace
motor.
103
Horizontal motor current over maximum
mA during enable
Session cancelled to avoid overcurrent to horizontal
motor.
•
Check Voltage to the motor (24V DC)
•
If voltage is good check for obstructions or
tubing hanging up