Mystic Tan Kyss™
Owner’s Manual
32
Clean Float Switch Plate and Sump Basin
An in-depth cleaning of the float switch plate and sump basin should be performed
monthly and extends beyond rinsing the filter. Repeated failure to perform this action
could lead to clogging of the sump basin and sticking float sensors, which could register
as a booth fault and cause problems when trying to run a session.
Carefully remove the bottom
panel by pulling out on the
handle. If the panel has an
accumulation of solution, clean
with warm water and Dawn or
other mild detergent.
Clean the sump basin and remove any
debris. Use a nonabrasive cloth and
warm water to clear any sediment that
may have accumulated.
Once the sump basin and float switch plate have been cleaned,
carefully reassemble the components back into place. Go to
the Staff > Tools page and run a manual rinse followed by a
manual drain and verify that the water drains properly.
Being careful
not to damage the float sensors
in any way, lift up the float switch plate and
carefully
clean both floats. Do not use
excessive force on the floats.
Drain Float
Emergency
Float