Suniva OPTIMUS Installation and Instruction Manual 

Introduction 

This  manual  provides  safety  and  installation  instructions  for 
Suniva photovoltaic  modules, herein referred to as module(s),

 

with the followings model numbers:

 

  OPT2XX-60-4-YYY;  Where  XX  could  be  35  to  65  in 

increments  of  5.  YYY  could  be  either  100,  101,  1B0  or 
1B1 

To maintain the safety of yourself and others, carefully read the 
entire installation and instruction sheet prior to installation and 
operation.    System  safety  and  proper  design  should  be 
ensured  by  qualified  personnel.  Failure  to  comply  with  these 
instructions  will  invalidate  the  Suniva  Limited Warranty  for  the 
module. For more information, please visit our website. 

Safety 

  Suniva  modules  produce  electricity  when  exposed  to  light. 

To avoid electric shock and injury, completely cover the front 
of  the  module  with  an  opaque  material  before  making  any 
electrical  connections  and  disconnect  the  module  from  all 
electrical connections before any maintenance or cleaning.  

  Only  individuals  trained  in  the  principles  of  electricity  and 

electrical equipment should install modules.  

  Modules  must  be  installed  in  a  manner  compliant  with 

applicable local regulations or requirements. 

  Use  properly  insulated  tools  and  appropriate  protective 

equipment and work only in dry conditions. 

  Protective gloves should be worn when handling modules to 

protect against sharp edges and burns. 

  Do not artificially concentrate sunlight on the module(s). 

  Do  not  install  the  modules  in an  area  where  flammable gas 

or material may be present. 

  Do  not  remove  any  part  installed  by  a  qualified  installer,  or 

disassemble the module in any way. 

  Use original packaging to transport and store module. 

  Avoid excessive bending and twisting of the module.  

  Do  not  exert  excessive  loads  on  the  module.  Do  not 

step/stand on the module. 

  Avoid  wearing  metallic  jewelry  when  installing  or  handling 

the module to protect against electric shock.  

  Do not leave the module unsupported or loosely fixed during 

or prior to installation and avoid installing during heavy winds. 

  Do  not  attempt  to  repair  a  broken  or  damaged  module, 

replace  immediately  to  avoid  fire  danger  and  shock  hazard. 
Use  caution  when  handling  as  damaged  modules  may 
conduct electricity to the frame. 

Product Information 

  This 60-cell solar module can be used in series and parallel 

array configurations or as a stand-alone system. 

  For IEC installations: This module is certified to IEC 61730-1 

and IEC 61730-2 for application Class A and is rated for use 
in systems operating at voltages greater than 50 VDC or 240 
W, where general contact access is expected. And for Class 
A  applications  this  module  meets  requirements  of  Safety 
Class II as defined by IEC 61140. 

  The allowable operating temperatures range of the module is 

185 

F to -40 

F (85 

C to -40 

C). 

Serial Number 

  The  structure  of  the  module  serial  number  provides  the 

following information: 
Example: SJWSH00011103310017 
S-JWSH-0001 

– 11– 03 – 31 - 0017 

A-BBCC-DDDD-EE-FF-GG-HHHH 

 
A: 

Manufacturer; BB: Factory; CC: Factory Location 

DDDD:  Engineering  Number;  EE:  Year  of  Production;  FF: 
Month of Production; GG: Date of Production; HHHH: 4 digit 
sequence  0  to  9999  for  sequential  production  starting  on 
each new day of production at 0001. 

Electrical Characteristics 

  See  tables  at  end  of  installation  manual  for  electrical 

parameters. 

  The  electrical  characteristics  are  within  ±10  percent  of  the 

indicated  values  of  I

SC

,  V

OC

,  and  P

MAX

  under  standard  test 

conditions; irradiance of 100 mW/cm

2

, AM 1.5 spectrum, and 

a cell temperature of 25°C (77°F). 

  Maximum series fuse rating is 15 A 

  This  module is  rated  for  use  in  systems of  up  to  1000  V  for 

TUV/IEC and 600 V for UL 

  Under  normal  conditions,  a  photovoltaic  module  is  likely  to 

experience  conditions  that  produce  more  current  and/or 
voltage  than  reported  at  standard  test  conditions. 
Accordingly,  the  values  of  I

SC

  and  V

OC

  marked  on  this 

module  should  be  multiplied  by  a  factor  of  1.25  when 
determining 

component 

voltage 

ratings, 

conductor 

ampacities, fuse sizes, and size of controls connected to the 
PV output.  

Temperature Coefficients 

Temperature Coefficients 

Power 

γ, Pmax (%/°C) 

- 0.450 

Voltage 

ß, Voc (%/°C) 

- 0.335 

Current 

α, Isc (%/°C) 

+ 0.047 

NOCT 

46 +/- 2 

Mounting Overview 

  Mounting  design  and  installation  should  be  performed  by 

trained professional and must conform to local codes. 

  Select a site and configuration that maximizes direct sunlight 

exposure and eliminates or minimizes shadowing. 

  Avoid  small  tilt  angles  to  prevent  the  accumulation  of 

dirt/debris along module edge. 

  Improper  mounting  of  the  module(s)  can  lead  to  damage  or 

injury  and  will  void  the  warranty.  Do  not  drill  additional 
mounting  holes  into  module  frames.  This  will  void  the 
warranty. 

  The  module(s)  should  be  fixed  in  a  manner  that  withstands 

all  expected  loads,  including  those  caused  by  wind,  snow 
and ice. Verify by certified engineer. 

  Orient  the  module  junction  box  in  such  a  way  and  provide 

clearance  between  the module  frame  and  mounting  surface 
to ensure that water cannot build up at the junction box and 
so the junction box does not contact the mounting surface. 

  The module has a Class C Fire Rating and must be installed 

on a roof with appropriate fire resistance. Consult your local 
building  authority  or  fire  department  to  determine  approved 
roofing materials. 

  If  the  module  is  to  be  mounted  to  a  roof  of  a  building,  the 

assembly  must  be  mounted  over  a  fire  resistant  roof 
covering suitable for the application. A slope less than 5 in/ft 
(127 mm/305mm) is required to maintain the fire class rating.  

Mounting Instructions 

  It  is  acceptable  to  mount  this  module  using  bolts  or  clamps 