Suniva OPTIMUS Installation and Instruction Manual
Introduction
This manual provides safety and installation instructions for
Suniva photovoltaic modules, herein referred to as module(s),
with the followings model numbers:
OPT2XX-60-4-YYY; Where XX could be 35 to 65 in
increments of 5. YYY could be either 100, 101, 1B0 or
1B1
To maintain the safety of yourself and others, carefully read the
entire installation and instruction sheet prior to installation and
operation. System safety and proper design should be
ensured by qualified personnel. Failure to comply with these
instructions will invalidate the Suniva Limited Warranty for the
module. For more information, please visit our website.
Safety
Suniva modules produce electricity when exposed to light.
To avoid electric shock and injury, completely cover the front
of the module with an opaque material before making any
electrical connections and disconnect the module from all
electrical connections before any maintenance or cleaning.
Only individuals trained in the principles of electricity and
electrical equipment should install modules.
Modules must be installed in a manner compliant with
applicable local regulations or requirements.
Use properly insulated tools and appropriate protective
equipment and work only in dry conditions.
Protective gloves should be worn when handling modules to
protect against sharp edges and burns.
Do not artificially concentrate sunlight on the module(s).
Do not install the modules in an area where flammable gas
or material may be present.
Do not remove any part installed by a qualified installer, or
disassemble the module in any way.
Use original packaging to transport and store module.
Avoid excessive bending and twisting of the module.
Do not exert excessive loads on the module. Do not
step/stand on the module.
Avoid wearing metallic jewelry when installing or handling
the module to protect against electric shock.
Do not leave the module unsupported or loosely fixed during
or prior to installation and avoid installing during heavy winds.
Do not attempt to repair a broken or damaged module,
replace immediately to avoid fire danger and shock hazard.
Use caution when handling as damaged modules may
conduct electricity to the frame.
Product Information
This 60-cell solar module can be used in series and parallel
array configurations or as a stand-alone system.
For IEC installations: This module is certified to IEC 61730-1
and IEC 61730-2 for application Class A and is rated for use
in systems operating at voltages greater than 50 VDC or 240
W, where general contact access is expected. And for Class
A applications this module meets requirements of Safety
Class II as defined by IEC 61140.
The allowable operating temperatures range of the module is
185
⁰
F to -40
⁰
F (85
⁰
C to -40
⁰
C).
Serial Number
The structure of the module serial number provides the
following information:
Example: SJWSH00011103310017
S-JWSH-0001
– 11– 03 – 31 - 0017
A-BBCC-DDDD-EE-FF-GG-HHHH
A:
Manufacturer; BB: Factory; CC: Factory Location
DDDD: Engineering Number; EE: Year of Production; FF:
Month of Production; GG: Date of Production; HHHH: 4 digit
sequence 0 to 9999 for sequential production starting on
each new day of production at 0001.
Electrical Characteristics
See tables at end of installation manual for electrical
parameters.
The electrical characteristics are within ±10 percent of the
indicated values of I
SC
, V
OC
, and P
MAX
under standard test
conditions; irradiance of 100 mW/cm
2
, AM 1.5 spectrum, and
a cell temperature of 25°C (77°F).
Maximum series fuse rating is 15 A
This module is rated for use in systems of up to 1000 V for
TUV/IEC and 600 V for UL
Under normal conditions, a photovoltaic module is likely to
experience conditions that produce more current and/or
voltage than reported at standard test conditions.
Accordingly, the values of I
SC
and V
OC
marked on this
module should be multiplied by a factor of 1.25 when
determining
component
voltage
ratings,
conductor
ampacities, fuse sizes, and size of controls connected to the
PV output.
Temperature Coefficients
Temperature Coefficients
Power
γ, Pmax (%/°C)
- 0.450
Voltage
ß, Voc (%/°C)
- 0.335
Current
α, Isc (%/°C)
+ 0.047
NOCT
C
46 +/- 2
Mounting Overview
Mounting design and installation should be performed by
trained professional and must conform to local codes.
Select a site and configuration that maximizes direct sunlight
exposure and eliminates or minimizes shadowing.
Avoid small tilt angles to prevent the accumulation of
dirt/debris along module edge.
Improper mounting of the module(s) can lead to damage or
injury and will void the warranty. Do not drill additional
mounting holes into module frames. This will void the
warranty.
The module(s) should be fixed in a manner that withstands
all expected loads, including those caused by wind, snow
and ice. Verify by certified engineer.
Orient the module junction box in such a way and provide
clearance between the module frame and mounting surface
to ensure that water cannot build up at the junction box and
so the junction box does not contact the mounting surface.
The module has a Class C Fire Rating and must be installed
on a roof with appropriate fire resistance. Consult your local
building authority or fire department to determine approved
roofing materials.
If the module is to be mounted to a roof of a building, the
assembly must be mounted over a fire resistant roof
covering suitable for the application. A slope less than 5 in/ft
(127 mm/305mm) is required to maintain the fire class rating.
Mounting Instructions
It is acceptable to mount this module using bolts or clamps