background image

10 

 

ASSEMBLY INSTRUCTIONS CONTINUED 

 

Use the pressure regulator supplied with the appliance. 

The installation must conform with local codes, or in the absence of local codes, with 
National Fuel Gas Code, ANDZ223.1/NFPA54, Natural Gas and Propane Installation 
Code, CSAB149.1, or Propane storage and handling code, B149.2. 

Certain materials or items, when stored under the heater, will be subjected to radiant heat 
and could be seriously damaged. 

Only use a cylinder marked “propane”. 

A dented, rusted, or damaged propane cylinder may be hazardous and should be checked 
by your cylinder supplier. Never use a propane cylinder with a damaged valve connec-
tion. 

The propane cylinder must be constructed and marked in accordance with the specifica-
tions for LP gas cylinders of the U.S. Department of Dangerous Goods and Commission, 
CAN/CSA-B339. 

Includes a listed overfilling prevention device. 

Includes a cylinder connection device compatible with the connection for the appliance.  

The cylinder used must include a collar to protect the cylinder valve.  

Never connect an unregulated propane cylinder to the heater. 

 

Move the burner control knob to the off position. 
Fix the 1.02 lb. propane cylinder to the regulator 
(rotate the propane cylinder clockwise toward the 
regulator connecting until tight). 

 
Close the door plate and lock it with the handle. 

 

Disconnect the cylinder when the appliance is not 
in use 

Store the appliance in a shelter: 

A.  With walls on all sides, but with no overhead cover 

B.  Within a partial enclosure which includes an overhead cover and no more than two 

side walls. These side walls may be parallel, as in a breezeway, or at right angles to 
each other.  

C.  Within a partial enclosure which includes an overhead cover and three side walls, as 

long as 30% or more of the horizontal periphery of the enclosure is permanently 
open. 

11 

 

Use a replacement pressure regulator specified by the appliance manufacturer. Use 
the pressure regulator and hose assembly supplied with the appliance. 
 

OPERATION INSTRUCTIONS 

 
Portable Heater Location 
 

1.  This portable heater is intended for outdoor use only. Always ensure adequate fresh 

air ventilation.  

2.  Always  maintain  proper  clearance  to  combustible  materials:  a  minimum  of  24  in. 

from the top and 36 in. from the sides. 

3.  Place the heater on a strong and stable table.  
4.  Never operate the heater in an explosive atmosphere like in areas where gasoline or 

other flammable liquids or vapors are stored. 

 
 

Testing for Leakage 

Gas connections on this heater are  leak tested at the  factory prior to shipment.  Possible 
mishandling of this appliance during shipping may impair integrity.  Perform a complete 
leakage test again at the installation site. Please follow the procedure below: 
 
1.  Make a soap solution of one part liquid detergent and one part water. The soap solu-

tion can be applied to hoses and connections with a spray bottle, brush, or rag. 

2.  Make sure that the safety control valve is in the “OFF” position. 
3.  Turn  the  cylinder  valve  “ON”  and  check  for  soap  bubbles  forming  on  and  around 

connections and hoses. If bubbles appear, there is a leak present. 

4.  If a leak is present, remove the gas cylinder immediately, tighten any leaking fittings, 

replace the gas cylinder, and recheck. 

 
 

Procedure for Leakage Test 

1.  Periodically check the whole gas system for leaks 
2.  Immediately check for leaks in an odor of gas is detected. 
3.  Extinguish all open flames during testing or when an odor of gas is detected. 
4.  Never smoke while performing the leak test, 
5.  If you cannot stop a leak, unscrew and remove the cylinder from the heater.  
6.  Check the heater with a full propane cylinder. DO NOT use the heater until you have 

performed a leak test on all the connections and verified that your unit does not leak.  

7.  Use  only  manufacturer  recommended  replacement  parts.  Substitution  may  void  the 

warranty. 

 

Do not store a spare LP-gas cylinder under or near this appliance; 

 

Never fill the cylinder beyond 80 percent full; 

 

Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. 
Only install the type of dust cap on the cylinder valve that is provided with the 
cylinder valve. Other type of caps or plugs may result in leakage of propane.

 

Содержание PHSQGH-TT

Страница 1: ...20 OPERATION MANUAL AND WARRANTY INFRARED PATIO HEATERS Model PHSQGH TT SAFE SOFT COMFORTABLE PLEASE READ THIS MANUAL...

Страница 2: ...CLIP AND RETURN THE WARRANTY CARD BELOW _______________________________________________________________ SUNHEAT Warranty Registration Please return this card within 30 days of purchase to activate you...

Страница 3: ...Warranty Service Center or to the address below All transporta tion charges are the responsibility of the consumer A copy of the original receipt must accompany all warranty claims SUNHEAT Internation...

Страница 4: ...pilot ob tain new igniter and replace Pilot won t stay lit Dirt built up around pilot Clean dirt from around pilot Connection between gas valve and pilot assembly is loose Tighten connection and per...

Страница 5: ...and is also located throughout the manual Keep this manual for future reference and to educate new users of this product This manual should be read in conjunction with the labeling on the product Saf...

Страница 6: ...performance from your heater make sure you perform the following maintenance activities on a regular basis Keep exterior surfaces clean 1 Use warm soapy water for cleaning Never use flammable or corro...

Страница 7: ...ation service or maintenance can cause property dam age injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment 3 We canno...

Страница 8: ...ck air flow into or out of the heater 11 Carbon monoxide CO poisoning produces flu like symptoms watery eyes headaches dizzi ness fatigue and possibly death You can t see it and you can t smell it It...

Страница 9: ...ecified by the manufacturer Lighting Note This heater is equipped with a pilot light that allows for safer startups and shut downs Pilot must be lit before main burner can be started 1 Turn the contro...

Страница 10: ...TION INSTRUCTIONS Portable Heater Location 1 This portable heater is intended for outdoor use only Always ensure adequate fresh air ventilation 2 Always maintain proper clearance to combustible materi...

Отзывы: