5.2 Terminal Description
All electrical terminals are located at the bottom of the inverter.
1
2
5
3
4
PV2
PV2
PV1
PV1
Fig. 5-1
Terminal Description
* Image shown here is for reference only. The actual product you receive may
differ.
Tab. 5-1
Terminal Descriptions
Item
Terminal
Description
1
PV terminals
MC4 terminals for PV inputs.
-S series:
one pair of PV terminals.
-D series:
three pairs for SG8K-D and two pairs
for other –D inverters.
2
RS485 terminal
To connect a Wi-Fi module.
3
Meter | DRM
terminal
The left hole is for meter communication and the
right is for DRED communication.
4
Additional
grounding terminal
For reliable grounding.
5
AC terminal
The AC terminal to the utility grid.
5.3 Cable Requirements
No.
Cable
Inverter Model
Specification
Outer
diameter
(mm)
Conductor
Cross-section
(mm
2
)
1
AC cable
(1)
SG2K-S / SG2K5-S
/ SG3K-S / SG3K-D
10–14
4–6
SG5K-D
10–14
4–6
SG8K-D
15
6
2
PV cable
(2)
All
6–9
4–6
3
Additional
grounding cable
All
/
4–6