10.2 Wring Distance of DI Dry Contact
The maximum wiring distance of DC dry contact must meet the requirements in the
table below. The wiring distance L is the total length of all DI signal cables.
L
K
refers to the cable length between the DI dry contact terminal of the k
th
inverter and
the corresponding terminal of the (k-1)
th
inverter.
Table 10-1
Correspondence between number of inverters and maximum wiring distance
N
Nu
um
mb
be
err o
off
iin
nvve
errtte
err
M
Ma
axxiim
mu
um
m w
wiirriin
ng
g d
diisstta
an
nc
ce
e((u
un
niitt::m
m))
1
16
6A
AW
WG
G // 1
1..3
31
1m
mm
m
2
2
1
17
7A
AW
WG
G // 1
1..0
02
26
6m
mm
m
2
2
1
13030
10552
2
6515
5276
3
4343
3517
4
3258
2638
5
2606
2110
6
2172
1759
7
1861
1507
8
1629
1319
9
1448
1172
10
1303
1055
11
1185
959
12
1086
879
13
1002
812
14
931
754
15
869
703
16
814
660
17
766
621
18
724
586
19
686
555
20
652
528
21
620
502
22
592
480