Grid undervoltage,
the grid voltage is
lower than the set
protection value
Generally, the inverter will be reconnected
to the grid after the grid returns to normal. If
the fault occurs repeatedly:
1. Measure the actual grid voltage, and
contact the local electric power company
for solutions if the grid voltage is lower than
the set value.
2. Check whether the protection parameters
are appropriately set via the App.
3. Check whether the AC cable is firmly
connected in place.
4. If the fault is not caused by the foregoing
reasons and still exists, contact SUNGROW.
005
Grid low voltage,
the grid voltage is
lower than the set
protection value
Generally, the inverter will be reconnected
to the grid after the grid returns to normal. If
the fault occurs repeatedly:
1. Measure the actual grid voltage, and
contact the local electric power company
for solutions if the grid voltage is lower than
the set value.
2. Check whether the protection parameters
are appropriately set via the App.
3. Check whether the AC cable is firmly
connected in place.
4. If the fault is not caused by the foregoing
reasons and still exists, contact SUNGROW.
007
AC instantaneous
overcurrent, AC output
current exceeds the
upper limit of the
inverter.
Generally, the inverter will be reconnected
to the grid after the grid returns to normal. If
the fault occurs repeatedly, contact
SUNGROW.
User Manual
Содержание SG125HX
Страница 1: ...User Manual PV Grid Connected Inverter SG125HX SG125HX UEN Ver14 202105 WWW SUNGROWPOWER COM...
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 32: ...22 E En nd d 4 Mechanical Mounting User Manual...
Страница 45: ...35 Ensure that the depth L of the socket used is not less than 28mm User Manual 5 Electrical Connection...