44
ffiig
gu
urre
e 5
5--6
6 Multi-inverter Connection
When more than 15 inverters are connected to the same daisy chain, in order to ensure
the communication quality, the Logger at the first end of the daisy chain needs to be
equipped with a terminal resistor of 120Ω, the inverter at the last end needs to be
equipped with a RS485-dip switch (SW1), and the shielding layer of the communication
cable should be single-point grounded.
ffiig
gu
urre
e 5
5--7
7 Configuration of Dip Switch (N≥15)
The length of the RS485 cable and twisted pair cable should be no longer than
1,200m.
If multiple inverters are connected to the data logger, the number of
permissible daisy chains and the number of devices allowed to be connected
should meet the requirements (refer to the user manual for the data logger).
User Manual
Содержание SG125HX
Страница 1: ...User Manual PV Grid Connected Inverter SG125HX SG125HX UEN Ver14 202105 WWW SUNGROWPOWER COM...
Страница 2: ......
Страница 6: ......
Страница 10: ......
Страница 32: ...22 E En nd d 4 Mechanical Mounting User Manual...
Страница 45: ...35 Ensure that the depth L of the socket used is not less than 28mm User Manual 5 Electrical Connection...