User Manual
43
No. Name
Description
7
DC PE terminal
DC PE cable access, M6
×
16 (right) or
M10X30 (left)fastening screws
8
Waterproof air valve
-
9
Communication cable
gland
For Communication cable connection
Knockout diameter for communication
cable is 28.5mm.
10*
DC cable gland
For DC cable connection
Knockout diameter for DC cable is 75.8mm.
(The proper range of DC cable external
diameter is 20~26mm)
11*
AC cable gland
For AC cable connection
Knockout diameter for AC cable is 75.8mm.
(The proper range of AC cable external
diameter is 38~56mm)
12
AC cable gland for
connecting Tracker control
cabinet
Reseved
13
DC input plug-in terminal
for connecting Tracker
control cabinet
Reseved
Connect the cable through the corresponding interfaces on the bottom
of the inverter during power cable and communication cable
connection;
Tie the communication cables (e.g. RS485 and the dry contact) to
prevent interference with the power cables.
*