The anti-cavitation valve is designed for Sunfab SCM motors in applica-
tions that have a relatively large rotating mass with a long rundown time. 
When using the anti-cavitation valve, the hydraulic motor must only be 
used in one direction of rotation.

1.  DIRECTION OF ROTATION OF THE HYDRAULIC MOTOR

The anti cavitation valve is always supplied with the check valve mounted 
so that the input pressure to the motor is on port V2. If the opposite direc-
tion of rotation is required, move the check valve from V2 to V1 as in the 
figure.

In order to switch the direction of rotation on valves intended for SCM 
084-130 rotate the whole valve block 180°

2. ASSEMBLY

• Clean the contact surface on the motor.

• Fit the valve on the motor using appropriate seals, flanges, screws, or 
banjo bolts.

• Tighten the screws crosswise as shown in the diagram. 

See the table for screw dimensions and tightening torques for each valve 
size.

Type SCM 

012-034  040-064  084-130 

Screw dimension (Grade 12.9) 

– 

M10x80  M12x90

Banjo bolt 

G 3/4 

– 

Tightening torque (Nm) 

160/118 

75/55 

130/96

Otherwise see SCM motor installation guide 751.

3.  ASSEMBLY AND SAFETY INSTRUCTIONS

Only perform the installation when the machine in question is turned off.

INSTALLATIONS ANVISNING

Återfyllnadsventilen är avsedd för Sunfab SCM-motorer i applikationer 
som har relativt stor roterande massa med lång utrullningstid. Vid an-
vändning av återfyllnadsventilen måste hydraulmotorn användas i endast 
en rotationsriktning.

1.  HYDRAULMOTORNS ROTATIONSRIKTNING

Återfyllnadsventilen levereras alltid med backventilen monterad så att 
inkommande tryck till motorn monteras på port V2. Önskas motsatt rota-
tionsriktning flyttas backventilen från V2 till V1 enligt figur.

För att skifta rotationsriktning på ventilen avsedd för SCM 084-130  
roteras hela ventilblocket 180°

2. MONTERING

• Rengör anliggningsplanet på motorn.

• Montera ventilen mot motorn med avsedda tätningar, flänsar och skruvar, 
alternativt banjobultar.

• Korsdra skruvarna enl. schema. 

Se tabell för skruvdimension och åtdragningsmoment för respektive 
ventilstorlek.

Typ SCM 

012-034  040-064  084-130 

Skruvdimension (Kvalité 12.9) 

– 

M10x80  M12x90

Banjobult 

G 3/4 

– 

Åtdragningsmoment (Nm) 

160 

75 

130

Se i övrigt SCM motorns installationsanvisning 751.

3.  MONTERINGS- OCH SÄKERHETSANVISNINGAR

Utför installation endast när den aktuella maskinen är avstängd.

767  GB/US | SE | DE | ES | FR | IT | PL | RU 

 

ANTI-CAVITATION VALVE

Содержание 012-034

Страница 1: ... Tightening torque Nm 160 118 75 55 130 96 Otherwise see SCM motor installation guide 751 3 ASSEMBLY AND SAFETY INSTRUCTIONS Only perform the installation when the machine in question is turned off INSTALLATIONS ANVISNING Återfyllnadsventilen är avsedd för Sunfab SCM motorer i applikationer som har relativt stor roterande massa med lång utrullningstid Vid an vändning av återfyllnadsventilen måste ...

Страница 2: ...ageanleitung 751 für SCM Motoren 3 MONTAGE UND SICHERHEITSANWEISUNGEN Führen Sie die Installation nur an einer abgeschalteten Maschine durch INSTRUCCIONES DE MONTAJE La válvula anticavitación ha sido diseñada para los motores SCM de Sunfab instalados en aplicaciones con una masa giratoria relativamente elevada y un tiempo de parada prolongado La válvula anticavitación obliga a utilizar el mo tor h...

Страница 3: ...s instructions d installation des moteurs SCM 751 3 ASSEMBLAGE ET CONSIGNES DE SÉCURITÉ Procéder à l installation uniquement lorsque la machine est à l arrêt ISTRUZIONI PER L INSTALLAZIONE La valvola anticavitazione è progettata per i motori Sunfab SCM in ap plicazioni aventi massa rotante relativamente grande con un tempo di esaurimento prolungato Quando si utilizza la valvola anticavitazione il ...

Страница 4: ...10 x 80 M12 x 90 Барашковый болт G 3 4 Момент затяжки Н м 160 75 130 Более подробные сведения содержатся в руководстве по монтажу двигателя 751 3 УКАЗАНИЯ ПО СБОРКЕ И ТЕХНИКЕ БЕЗОПАСНОСТИ Выполняйте работы по монтажу только при выключенном оборудовании INSTRUKCJA INSTALACJI Zawór antykawitacyjny jest przeznaczony do silników SCM firmy Sunfab w za stosowaniach mających stosunkowo dużą masę obrotową...

Страница 5: ...094 SE 824 12 Hudiksvall Sweden Tel 46 650 367 00 Fax 46 650 367 27 E mail sunfab sunfab se Web www sunfab com 1310 5 5 ANTI CAVITATION VALVE 4 8 6 2 1 5 7 3 V2 V1 V2 V1 012 034 140 Nm 103 lbf ft 040 064 280 Nm 207 lbf ft 2 2 1 ...

Отзывы: