Forced Health Improvement (FHI®):

Frequent cycling of the battery at a very low state of charge causes 
fast deterioration of the battery due to sulphation and stratification. 
The Apple will not allow the User to frequently operate the battery at 
low state of charge. After reaching a forced Low Voltage Disconnect 
(LVD), the user will not be able to discharge the battery to the same 
low level again next day. This is indicated to the user with a yellow LED 
Penalty mode. Only after reaching the Boost Charge level of 14.5V the 
Penalty mode will be reset and the Apple will allow the user to use the 
full battery capacity again.

The Apple is available in 3 standard charge/discharge current 
capacities 5, 10 and 15 Amperes. With its clean and round appearance, 
and all cable connections nicely covered at the backside of the unit, 
the Apple is esthetically attractive for indoor installation.

 

The "Apple" is a unique small PV charge/discharge controller in the 
Sundaya product range, specially designed for cost-effective applications 
based on SMD technology. The Apple is extremely power- efficient due to 
its very low voltage drop over both input and output switching Mosfets. 
Unique features include Forced Health Improvement (FHI®) algorithm, 
and a buzzer to remind the User of the battery’s SOC (State of Charge) as 
it gets close to LVD (Low Voltage Disconnect). Furthermore, it comes with 
a self-reset electronic master-switch, so that whenever the Apple is 
reconnected to the battery or simply newly installed, the output will 
always stay inactive until the user presses on the reset switch. A SOC 
(State of Charge) indicator gives clear indication of the battery's status.

Product Description

Main Features:

# Strong input and output connectors with clear polarity markings
# Cable connectors not reachable and not visible after mounting on the 

wall (safety and esthetic reasons)

# Extremely low voltage drop over power mosfets
# Boost Charge mode
# LED Indicator for charging
# LED Indicator for state of charge in 8 steps
# Electronic Overload/Short circuit protection with LED Indicator
# Electronic Master-switch to centrally cut off all loads
# Deep discharge cut off with LED Indicator
# Forced Health Improvement (FHI®) feature

1  8-steps SOC (State of Charge) LED Indicator

To indicate the SOC of the batteries, the SOC level is proportional to the 
numbers of the LEDs lit up. 

Example

:   All 8 LEDs lit up indicate the 

batteries are fully charged (SOC = 12.7 - 13.1V);   Only the first (lowest) 
LEDs lit up indicate the batteries close to exhaustion, the output of the 
controller will soon be cut if the LOAD continues to be connected 
without sufficient charging to replenish the batteries (SOC = 11.4 - 
11.7V).

2. 

Deep discharge Cut-Off LED Indicator

To indicate that the controller disconnected the output due to SOC 
falling below 11.9 V +/- 0.10 V on Penalty mode, or 11.5V +/- 0.10 V on 
Non Penalty mode.

3. 

Display Button

    The 8-steps SOC (State of Charge) LED Indicator, Deep discharge Cut-Off 

LED Indicator, Master-switch / Overload/Short circuit LED Indicator, and 
Penalty mode LED Indicator will display the status only when the Display 
Button pressed

.

4. 

On/Off Master-Switch

Toggle the controller output from on to off, or off to on by pressing the 
switch once. 

5. 

Master-switch / Overload/Short circuit LED Indicator

The LED Indicator will light up when the User turns off the output by 
pressing the On/Off Master-Switch once, or the controller cuts off the 
output due to a short circuit detected.

6. 

Penalty mode LED Indicator

The LED Indicator will light up when the Penalty mode is in effect, due to: 

 - During controller’s first power up, the SOC of  the battery is below 12.7V
 - After the controller disconnected the output due to SOC falling below   
   11.9 V +/- 0.10 V on Penalty mode, or 11.5V +/- 0.10 V on Non Penalty        
    mode.

7. 

Charging LED Indicator

The LED Indicator will light up when charging take place.

LED Indicators and Button/Switch Description:

 

11

1

2

3

5

6

7

4

#

 Sundaya

Battery Terminal 

Connector

Load Terminal 

Connector

PV Terminal 

Connector

#

 Sundaya

#

 Sundaya

6. Press the On/Off Master-Switch, and hold for one or two seconds, then 

release. The Load will turn on.

7. Connect the Solar Panel Input to either 12Vdc Solar modular or 12Vdc 

charger such as DC10. (Caution: - please make sure the positive and 
negative polarities are correctly connected)

8. The Charging LED Indicator should light up if charging is taking place.
9. Mount the controller in indoor environment with minimum exposure 

to rainwater, water spill or hot temperature such as cooking oven.

10. The surface to mount the controller should be of good isolated 

material such as brick wall, plastic, or wood. 

Installation procedure:

1. Unpack the controller.
2. Prepare a fully charged battery.
3. Connect the controller to the fully charged battery. (Caution: - please 

make sure the polarities are correctly connected)

4. Press on the Display Button. All the 8-steps SOC (State of Charge) LED 

Indicator should light up if the battery is fully charged.

5. Connect the controller output to the load. Ideally, use low power load 

first such as DC lighting product (Ulite3), to verify proper operation.  
(Caution: - please make sure the positive and negative polarities are 
correctly connected)

#

 Sundaya

Apple

User's Manual

#

 Sundaya

 

 

 

 

Sundaya Contact Information

Sundaya International Pte., Ltd.

Address

: II  Tampines street  92  

                           SINGAPORE 528872
E-mail

[email protected]

Web Site

:  www.sundaya.com

Telephone

: +65 6788 8345

Facsimile

: +65 6788 8749

Sundaya Indonesia, PT.

Address

: Jl. Pondok Randu No.38 

  Cengkareng, Jakarta Barat 

                           INDONESIA 11750
Telephone

: +62 21 541 6103-05

Facsimile

: +62 21 541 6106

 

 

 

 

Stage-1

: - When the Controller is first connected to a half charged       

battery (SOC < 12.7V).

 Penalty mode LED Indicator - on
 Load cut-off

Stage-2

: - After the battery is charged up to SOC > 12.7V.

 Load indicator on

Stage-3

: - After the battery fully charged (SOC > 14.5V)

 Penalty mode LED Indicator - off

   Controller entry to PWM mode to prevent the battery being 

over charged

    The Charging LED indicator will start to blink

Stage-4

: - The battery discharged to SOC < 11.7V.

  Warning buzzer on

Stage-5

: - The battery continues discharge to SOC < 11.5V.

  Deep discharge Cut-Off LED Indicator on
  Penalty mode LED Indicator on
  Load cut-off

Stage-6

: - The battery recharged back to SOC > 12.7V

  Deep discharge Cut-Off LED Indicator off

Load indicator on

Stage-7

: - Under the Penalty mode, the battery discharged to SOC < 

12.1V.

  Warning buzzer on

Stage-8

: - Under the Penalty mode, the battery continues to be 

discharged to SOC < 11.9V Load cut-off

Stage-9

: - The battery charged back to SOC > 12.7V

 Load indicator on
 After the battery fully charge (SOC > 14.5V)
 Penalty mode LED Indicator - off
 Controller entry PWM mode to prevent over charge

Safety:

 #  

User should ensure the surface for mounting the controller is 

sufficiently strong to carry the weight of the unit.

 # Short circuit of batteries could generate excessive heat and possibly 

melt down the cables, causing injury to the User. During installation or 
battery replacement it is advisable to connect and secure the battery 
cable to the controller first, before connecting to the terminals on the 
battery.

Warranty:

All Sundaya Controller are warranted for any defects caused by faulty 
components or factory error. Warranty period varies depending on the 
country. Please check with your local dealer for details.
The warranty will be void under the following conditions:

 -The Product shows signs of having been exposed to water spill or 
submerged in liquid.
 -The Product shows signs of being opened, or warranty seal is broken.
 -The Product shows signs of abuse or misuse.      

Mechanical Specification:

Enclosure Materials   :  ABS
Color 

            :  Green

Shape  

            :  Round

Size 

            :  120mm x 40mm

Terminals                      :  
               # 8mm width Input terminal for Battery (bottom side)
               # 8mm width Input terminal for Solar Panel (top side)
               # 8mm width Output terminal for Load (top side)

 

Operation:

Load  Connect Area

Buzzer Warning

Penalty Area

Remarks :

V

ol

ta

ge

Load

Penalty

STAGE - 1 STAGE - 2 STAGE - 3 STAGE - 4 STAGE - 5 STAGE - 6 STAGE - 7 STAGE - 8 STAGE - 9

11

12

13

14

15

Load Reconnect

Level

Penalty Mode

Disconnect level

Load Disconnect

Level

Penalty

Boost

Buzzer

Buzzer

Discharge

Charge

Load Reconnect

Penalty

Load Connect

Penalty Load

Load Reconnect

Load Disconnect

& Penalty ON

PWM Float Charge

Electrical Specification:

 Nominal operating Voltage                : 12VDC
Self consumption 

                : 4 mA

Current Model Apple 5  

                : 5 Amp -0% +25%

Current Model Apple 10                   : 10 Amp -0% +25%
Current Model Apple 15                   : 15 Amp -0% +25%
Low Voltage Buzzer Warning Level   : 11.70 V (Non-Penalty mode)
Low Voltage disconnect                   : 11.50 V +/- 0.10 V (Non- Penalty mode)
(Non-Penalty mode)   

                   (with discharge current 
                    compensation -0.04V/A)

Low Voltage Buzzer Warning Level  : 12.10 V (Penalty mode)

Low Voltage disconnect                   : 11.90V +/- 0.10V (Penalty mode)
(Penalty mode)     

                  (with discharge current
                  compensation -0.04V/A)

Load Reconnect level 

                : 12.70 V

Penalty mode reset  

                : 14.50V +/- 0.10V

Boost Charge Level @250c                 : 14.5V (with Temperature

                  compensation -0.02V/deg C)

PWM float Charge level  

                : 14.10V (with Temperature

 

                  compensation -0.02V/ deg C)

Warning:

 # Do not connect the controller to AC power.
 # Although all controllers are reverse polarity protected, User should 

ensure correct connection by respecting the polerities.

 # All controllers are designed for indoor uses only.
 # All solar panel or charger connected to the controller should be 

dedicated to 12Vdc applications, and the current suplied to the controller 
should be equal to or  smaller than the controller's output current.  For 
e

xample

: -

Apple-5

   - The maximum current input from solar panel or charger 

should NOT excess 5A. 

Apple-10

 - The maximum current input from solar panel or charger 

should NOT excess 10A. 

Apple-15

 - The maximum current input from solar panel or charger 

should NOT excess 15A. 

Содержание Apple

Страница 1: ...onnect the controller to the fully charged battery Caution please make sure the polarities are correctly connected 4 Press on the Display Button All the 8 steps SOC State of Charge LED Indicator should light up if the battery is fully charged 5 Connect the controller output to the load Ideally use low power load first such as DC lighting product Ulite3 to verify proper operation Caution please mak...

Страница 2: ...aster Switch Toggle the controller output from on to off or off to on by pressing the switch once Master switch Overload Short circuit LED This LED will light up when the User turns off the output by pressing the On Off Master Switch once or the controller cuts off the output due to a short circuit detected Charging LED This LED will light up when charging is taking place Installation procedure a ...

Страница 3: ... PWM float Charge level 14 10V with Temperature compensation 0 02V C Fault finding If you are using the load terminal and the loads won t turn on 1 When you first connect the Apple regulator to a battery the load terminal is turned off The load terminal is turned on by pressing the on off button You can check whether the loads are on or off by holding the display button on for about 10 seconds the...

Страница 4: ...ngen stiger over 12 6V 2 Dybde afladnings LED Viser at laderegulatoren har afbrudt forbruget fra batteriet 3 Display knap Lysdioderne vil vise status kun hvis man trykker på Display knappen 4 On Off Master Switch Tænder og slukker udgangen til forbrug ved tryk på knappen 5 Master switch overopladning kortslutnings LED Denne lysdiode vil lyse nå brugeren vil slukke for forbrug ved at trykke på Tænd...

Страница 5: ...ator har 2 års garanti mod defekte komponenter eller fabriks fejl Garantien vil blive ugyldig under følgende vilkår produktet viser tegn på at have været vådt eller været i flydende væsker produktet viser tegn på at den har været åbnet eller forseglingen er brudt produktet viser tegn på vold eller mishandling Mekaniske specifikationer Material ABS Plastic Farve Grøn Form Rund Mål 120mm x 40mm Term...

Страница 6: ...r eller TV til laderegulatoren 7 TV 14 inverter pumper eller andre apparater som bruger meget strøm eller mere end laderen er beregnet til tilsluttes direkte til batteriet Afmontering foregår i absolut omvendt rækkefølge Det gælder også når du kun skifter batteriet Alle elektriske apparater og lamper som tilsluttes gennem laderegulatoren må ikke bruge mere end 5Ampere Hvis du bruger to eller flere...

Страница 7: ...4 ...

Страница 8: ...Short Overload condition Indicator for battery cut off condition Mechanical Wiring Terminals 8mm width Input terminal for battery bottom side 8mm width Input terminal for solar panel top side 8mm width Output terminal for Load top side Enclosure Materials Fireretardant ABS UV stabilized Enclosure Color Light Green Connector material Brass Nickel plated Product dimensions HxDia 40mm x 120mm Nett pr...

Отзывы: