(3) Press
DISPLAY
to make the filter cycle programming characters disap-
pear from the screen and the main display return to showing water tempera-
ture. If no sensor is pressed within 30 seconds, the screen automatically
returns to the standard water temperature display.
At any time, you may check the programming of any aspect of the filter cycle
by first pressing
CYCLE
then moving through the menu by pressing either
CYCLE
or
SELECT.
The programming is changed only by pressing
UP
or
DOWN
during this process.
10.3 Programming The Optional Ozonator Cycle
The Sentry control system allows you to easily adjust two separate aspects
of the ozone cycle:
•
The time of day (start time) the ozonator begins operating.
•
The length of time (duration) the ozonator operates.
Programming Procedure:
(1) Press the
CYCLE
sensor once. “Adjust 1” indicator displays.
(2) Press
CYCLE
sensor a second time, “Adjust O
3
” indicator displays.
(3) Press
SELECT
sensor, “Start time” indicator displays. Press
UP
or
DOWN
sensor to set ozone start time in 30 minute increments.
(4) Press
SELECT
sensor, “Duration” indicator displays. Press
UP
or
DOWN
sensor to set ozone duration in 2 hour increments.
(5) Press
DISPLAY
sensor to exit setup and return to normal water
temperature display.
10.4 Locking Filter Cycle
You may keep the filter cycle program from being inadvertently altered by elec-
tronically “locking” it. To accomplish this, simply press
CYCLE
then,
within 30 seconds, press
DISPLAY, MODE
and
UP,
within five seconds each.
A padlock symbol will appear on the screen. In this state, the status of the
cycle programming may be checked, but may not be altered. To unlock the
filter cycle programming to make changes, simply press
DISPLAY, MODE
and
DOWN
within five seconds each.
10.5 Panel Lock
To help prevent unauthorized use of your hot tub, the Sentry controls incor-
porate a unique panel locking system which disables the controls on the
panel.
Page 25
ENGLISH
Содержание 850Export Series
Страница 1: ...850 Export Series Installation Owner s Manual ...
Страница 5: ...8 3 Jet Air Controls Diagram Optima Cameo Models 1a 1a 3 3 ...
Страница 47: ...Page 40 ENGLISH ...
Страница 48: ... ...