OPERATION INSTRUCTIONS FOR THE FLUSH FIT

 

REGISTER BOOSTER

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT NOTICE

MODEL: HC500

With the use of any electrical appliance, it is important to observe all basic precautions to minimize the risk associated with use, such as electrical shock, fire, or injury to 

persons. Read these instructions before using your Flush Fit Register Booster

.

1. The Flush Fit Register Booster

 will be as warm as the air that is delivered from the register of your forced air furnace and/or cooling system. The maximum temperature for 

the register is 140° Fahrenheit or 60° Centigrade. Your Flush Fit Register Booster

 should never be exposed to higher temperatures or temperatures below freezing.

2. Do not in any way block the air grilles of the Flush Fit Register Booster

. Pressure on the bottom or top grilles of the Flush Fit Register Booster

 may cause the fan impeller 

to contact these grilles and damage the unit. 

3. Unplug the Flush Fit Register Booster

 when not in use. Turn the unit off before unplugging.

4. Do not operate the Flush Fit Register Booster

 with a damaged plug or cord, if the unit malfunctions, becomes noisy when operating, has been dropped or otherwise 

damaged, or if the housing is damaged or broken. Discard or return the unit for inspection, replacement, or repair.

5. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. 

Arrange cord away from traffic area and where it will not be tripped over.

6. The Flush Fit Register Booster

 should never be exposed to moisture. Do not use the unit in an open window, bathroom, or laundry area where it may come in 

contact with water. 

7. The Flush Fit Register Booster

 is designed for indoor use only. 

8. Never insert any object or allow any object to enter the Flush Fit Register Booster

 through the bottom or top grilles, as this may damage the unit or cause it to malfunction. 

9. Do not use the Flush Fit Register Booster

 near flammables such as gasoline, paint, or natural gas. 

10. The Flush Fit Register Booster

 is intended for use as described in the instructions only. Other use may cause fire, electrical shock, damage to the unit, or injury to 

persons and will void any warranty by the manufacturer.

11. Do not use strong detergents or flammable liquids to clean the Flush Fit Register Booster

.

12. The housing of your Flush Fit Register Booster

 is sealed at the factory. THERE ARE NO SERVICEABLE PARTS INSIDE. Attempting to open the housing will expose you 

to dangerous electricity, may cause fire and will void any and all warranty.

Before cleaning the Flush Fit Register Booster

 disconnect the power cord from the outlet. Dust may be removed from the exterior surfaces using a soft cloth, the round 

brush attachment of your vacuum cleaner, or a cloth that has been lightly moistened with water and a mild, non-abrasive detergent. Dust accumulation in the interior of the 

unit may be removed by using the small round brush attachment of your vacuum cleaner. Accumulation of dust in the interior will be minimized by regular replacement of 

your furnace filter as recommended by the manufacturer.

(4” X 10”) WALL REGISTER APPLICATIONS 

INSTALLATION

CLEANING AND MAINTENANCE

IMPORTANT WARNINGS

ONE YEAR LIMITED WARRANTY

1. Drill (two) holes with a 3/16” drill bit from the bottom side of the Flush Fit Register Booster

 grille. The holes should be drilled in the pre-molded location as 

    pictured below.

2. Secure the Flush Fit Register Booster

 in place.

ADAPTOR PLATE SOLD SEPARATELY FOR REGISTERS UP TO 12”X6”

FITS 10” X 4” FLOOR & WALL REGISTERS

NEVER EXPOSE YOUR FLUSH FIT REGISTER BOOSTER™ TO TEMPERATURES OVER 140°F (60°C)

DO NOT INSTALL IN CEILING.

SUNCOURT INC.

P.O. Box 40

Durant, IA 52747-0040

1.800.999.FANS (3267)

www.suncourt.com

WNT500-0319-A04

Patent D595,832 and patent pending

PRINTED IN USA

Subject to the following limitations, Suncourt Inc. (manufacturer) warrants that the Flush Fit Register Booster

 will, for 1 (one) year from date of original retail purchase, but 

not exceeding 2 (two) years from date of manufacture, remain free from appearance of defects in workmanship or materials. This warranty is subject to the following 

limitations: (a) manufacturer’s liability is limited to the replacement or repair of the unit, as decided by the manufacturer; (b) a defective unit must be returned, prepaid, with 

proof of purchase, well packaged to avoid damage in transit; and (c) this warranty does not apply to defects resulting from the alteration, abuse, accidental damage, 

unauthorized repair, or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees, and conditions on manufacturer’s part, and the manufacturer shall 

have no tortious or other liability in respect to this Flush Fit Register Booster

. Ship unit to Suncourt Inc. only after obtaining a Return Goods Authorization (RGA) number. 

Returns without this RGA number will not be accepted. Actual product appearance may differ from illustrations. Suncourt reserves the right to modify any or all of its products' 

features, designs, components and specifications without notice.

WALL MOUNT DRILL HOLE LOCATION

The rotary Set Point knob selects the automatic 

on/off temperature setting for both heating and 

cooling. 

Press mode button to select operation:

    to stop operation.

    for continuous running.

    for automatic on/off to boost warm air.

    for automatic on/off to boost cool air. 

Press the fan speed 

button to toggle 

from low, medium 

and high speed. 

Speed Adjustment:

OPERATION SETTINGS

HEAT-COOL SETTING LOGIC   

 

 

This device is designed to turn on and off from temperature rise and fall.

If you want the Flush Fit Register Booster™ to turn on with warm air from your 

furnace set the mode to HEAT (↑).  If you want the Flush Fit Register Booster™ 

to turn on with cool air from the A/C set the mode to COOL (↓).  In either mode 

the fans will start when the temperature rises/falls above/below the setpoint.  

The fans will stop when the sensor detects the end of the heating/cooling cycle 

or if the temperature returns to the initial setpoint (which ever occurs first).  The 

setpoint is not adjusted to room temperature, but is instead adjusted to the 

warmer or cooler air temperature from your ductwork during a forced-air cycle. 

The Flush Fit Register Booster™ will operate properly if your whole-home thermostat fan mode is set to "on", but it is best to set your thermostat fan mode to "auto" during the 

initial setup procedure described below.  It is also necessary that your whole-home thermostat is at a consistent temperature setting during the HC500 temperature adjustment 

/ verification and also for 2-3 cycles prior to making your initial adjustments.

Temperature adjustments should be made with the highest booster fan speed selected so that verification of operation in steps 9 and 11 is readily apparent.  

STEPS FOR HEATING MODE 

When the red  HEAT (↑) light is on the Flush Fit Register Booster™ will turn on as temperature rises. Allow your unpacked unit to acclimate to room temperature for at least 1 

hour as noted in step 5 below.

1. Start the operation settings before the Flush Fit Register Booster™ is installed in the register boot.

2. Insert the small end of the power supply cord into the receptacle on the Flush Fit Register Booster™. Plug the power supply into your 110V outlet.  Additional length can be 

added to the power supply cord using a 2.1mm ID / 5.5mm OD low-voltage extension cord.

3. Press the mode button until the OFF light is lit. The OFF light will dim 4 seconds after this mode selection is confirmed.

4. Turn the rotary setpoint dial clockwise until it stops. DO NOT FORCE.

5. Keep the unit away from the existing register's warm airstream and allow the unit to acclimate to room temperature for 1 hour.

6. Place the Flush Fit Register Booster™ into the register opening only when the furnace blower is not operating.

7. Press the mode button twice. The red HEAT (↑) light will be lit and the booster fans will not be operating.

8. Wait for your furnace to turn on. 

(Do not adjust heat settings to force on.)

  Allow 60 seconds of furnace blower operation before proceeding to next step.  (Allow 120 

seconds for a heat pump system)

9. Slowly turn the rotary setpoint dial counterclockwise in a continuous motion until the fans turn on. Stop turning the knob immediately once the booster's fans begin to 

operate.  At the ideal pace, the dial should move across one "square" every 6-8 seconds.

10. The Flush Fit Register Booster™ is now set to turn on when the air from the central furnace reaching the register is sufficiently warm.

11. Allow the furnace cycle to end naturally and observe that the fans turn off.  If your furnace has a 'purge' cycle (60 seconds of blower operation after heating has stopped), 

the fans should stop toward the end of the purge cycle or several seconds later.  If your furnace does not have a purge cycle, the fans will continue operating after the blower 

has ended until the air in the ductwork is no longer warm.

12. Observe the next furnace cycle and make note of when the Flush Fit Register Booster™ fans turn on. 

HELPFUL TIP

You can re-visit step 12 as needed to find your ideal starting temperature.  A setpoint closer to room temperature will activate the booster fans sooner after the furnace starts.  

But a setpoint that is too close to room temperature will not allow the HC500 to operate.

STEPS FOR COOLING MODE

When the blue COOL (↓) light is on the Flush Fit Register Booster™ will turn on as temperature drops. Allow your unpacked unit to acclimate to room temperature for at least 1 

hour as noted in step 6 below.

1. Start the operation settings before the Flush Fit Register Booster™ is installed in the register boot.

2. Insert the small end of the power supply cord into the receptacle on the Flush Fit Register Booster™. Plug the power supply into your 110V outlet.  Additional length can be 

added to the power supply cord using a 2.1mm ID / 5.5mm OD low-voltage extension cord.

3. Press the mode button until the OFF light is lit. The OFF light will dim 4 seconds after this mode selection is confirmed.

4. Turn the rotary setpoint dial counter-clockwise until it stops. DO NOT FORCE.

5. Keep the unit away from the existing register's cool airstream and allow the unit to acclimate to room temperature for 1 hour.

6. Place the Flush Fit Register Booster™ into the register opening only when the air conditioning system is not operating.

7. Press the mode button three times. The blue COOL (↓) light will be lit and the fans will not be operating.

8. Wait for your air conditioning to start after an ordinary call from your whole home thermostat.  Allow 75 seconds of central blower operation before proceeding to next step.

9. Slowly turn the rotary setpoint dial clockwise in a continuous motion until the fans turn on. Stop turning the knob immediately once the booster's fans begin to operate.  At the 

ideal pace, the dial should move across one "square" every  6-8 seconds.

10. The Flush Fit Register Booster™ is now set to turn on when the air from the A/C reaching the register is sufficiently cool.

11. Allow the A/C cycle to end and observe that the fans turn off.  If your central blower has a 'purge' cycle (60 seconds of blower operation after cooling has stopped), the fans 

should stop toward the end of the purge cycle or several seconds later.  If your central blower does not have a purge cycle, the fans will continue operating after the blower has 

ended until the air in the ductwork is no longer cool.

12. Observe the next A/C cycle and make note of when the Flush Fit Register Booster™ fans turn on.

HELPFUL TIP

You can re-visit step 12 as needed to find your ideal starting temperature. A setpoint closer to room temperature will activate the booster fans sooner after the A/C starts.  

But a setpoint that is too close to room temperature will not allow the HC500 to operate.

To reduce observable noise, select the lowest booster fan speed that adequately delivers the required air to the room.

 

 

The Flush Fit Register Booster™ will help to maintain an ideal temperature in your otherwise problematic room. Since the initial temperature settings were made under 

less-than-ideal conditions, you may find after several days that the start time of the booster fans relative to the central blower starting has changed since your initial adjustments. 

This is especially true in cases where the overall improvement in room temperature is more pronounced. If necessary, revisit step 12 for either mode to adjust your booster to the 

improved room conditions.

STOP

[a]

[b]

1:15

0:06

STOP

REPEAT

REPEAT

[c]

[d]

0:06

Push x4

STOP

STOP

[a]

[b]

1:30

0:06

STOP

REPEAT

REPEAT

[c]

[d]

0:06

Push x4

STOP

?

?

?

?

?

?

12a.

 

If the fans do not start soon enough 

(within 75 seconds of central blower operation), make note of the dial position [a]. Move the dial slightly more 

counter clockwise [b] to choose a lower starting temperature setpoint (closer to room temperature).  Make very small adjustments and wait 6-8 seconds after 

each adjustment to observe if the booster's fans turn on during this furnace cycle.

IF FAN DOES NOT TURN ON WITHIN 75 SECONDS

12b.

 

If the booster fans do not turn on

 after making several adjustments this is because the initial temperature setting was too close to room temperature. You 

will need to set a higher starting temperature setpoint. To do this, return to your original dial position [c] and move the knob slightly more clockwise [d]. Now press 

the mode button repeatedly to quickly cycle through all modes and return to heat mode. This effectively 're-sets' the temperature logic. Your booster fan should turn 

on after 6-8 seconds. If it does not, turn the knob slightly more clockwise and cycle through the modes again. This reset/adjustment procedure can be done 

repeatedly and does not require that you remove the unit from its operating location. 

IF FAN DOES NOT TURN ON

12a. If the fans do not start soon enough

 (within 90 seconds of central blower operation), make note of the dial position [a]. Move the dial slightly more 

clockwise [b] to choose a higher starting temperature setpoint (closer to room temperature). Make very small adjustments and wait 6-8 seconds after each 

adjustment to observe if the booster's fans turn on during this air-conditioning cycle. 

IF FAN DOES NOT TURN ON WITHIN 90 SECONDS

12b. If the booster fans do not turn on

 after making several adjustments this is because the initial temperature setting was too close to room temperature. You 

will need to set a lower starting temperature setpoint. To do this, return to your original dial position [c] and move the knob slightly more counter-clockwise [d]. Now 

press the mode button repeatedly to quickly cycle through all modes and return to cool mode. This effectively 're-sets' the temperature logic. Your booster fan 

should turn on after 6-8 seconds. If it does not, turn the knob slightly more counter-clockwise and cycle through the modes again. This reset/adjustment procedure 

can be done repeatedly and does not require that you remove the unit from its operating location. 

IF FAN DOES NOT TURN ON