background image

WIRING DIAGRAM

SPECIFICATIONS

Voltage

Warranty

40W

Damp

SPCC+PS Lens

4.18lbs

100-277V

7 Years

Moisture Rating

Housing Material 

Weight

Wattage

EASY INSTALLATION

1.

Turn off circuit breaker before installing. 

2.

Place Ceiling Panel face down on flat surface. 

Unscrew left driver and set aside screw.

Optional: 

If using dimmer, unscrew right driver cover.

2x2 LED SELECTABLE

CEILING PANEL

Required Tools: 

Drill, Ladder, Hammer, Pliers, Tape Measure, 

Pencil, Philips Screwdriver, Leveler. 

Installation Manual

Recessed Mount

3.

Pop out knockout (choice of 5). 

Optional: 

If using dimmer, pop out 2

nd

 knockout.

4. Connect supply wires to Ceiling Panel wires 

with included wire nuts: 

Black to Black (Live)

White to White (Neutral)

Green to Green (Ground)

 OPTIONAL: 

To use dimming feature, connect 

pink and purple wires on Ceiling Panel to 

compatible dimmer (not included).

5.

Replace driver covers.

Tighten screws.

6. Set preferred color temperature using CCT on 

back of Ceiling Panel.

7.

Bend 4 protective brackets located on back of 

Ceiling Panel up 90

o

.

8. Turn brackets 90

o

.  Hook should face outside 

edge of Ceiling Panel.

9.  Turn on circuit breaker and test light.

L (black)

N (white)

ground wire

(green)

DIM- (pink)

DIM+ (purple)

Please review instructions carefully before proceeding.

Отзывы: