background image

Australia - 1800 316 962 | New Zealand 0800 21 8020

Assembly Manual

Содержание evolve 10

Страница 1: ...Australia 1800 316 962 New Zealand 0800 21 8020 Assembly Manual...

Страница 2: ...t that the sauna floor is level Checking with a large level is recommended If the floor is not level shimming or other remedies should be applied before assembling the sauna Place the sauna floor in t...

Страница 3: ...base Prop up one end of the front wall to enable connection of the door heater electrical lead Before installing the Front Wall ensure that the door heater electrical is protruding from bottom of Fro...

Страница 4: ...Be sure that the wire s connector is fully inserted into the floor base connector and that the threaded cuff is fully screwed onto the floor base connector Position Right Side Wall Lift the Right Sid...

Страница 5: ...This will help ensure that the two walls remain in contact and the fasteners connect The 2 sets of fasteners for the walls will connect when the Side Wall is raised sufficiently When you feel the fast...

Страница 6: ...onnect one set of fasteners and miss the other If there is an obvious gap in the corner between the two walls the fasteners have not connected and the raising and lowering procedure will need to be re...

Страница 7: ...into the channel in the floor base Repeat the raising up and sliding down procedure again to connect the Left Side wall to Back Wall and the the Left Side Wall to the Front Wall Connect one corner at...

Страница 8: ...on the top left side of the roof and feed the connector down through the opening Install the Sauna Roof Lift the roof up and over top of the sauna walls If you are installing the sauna in a restrictiv...

Страница 9: ...oof Lower Roof into Position This wire brings power to the roof for the stereo and lighting components Under Bench Electrical NOTE Do not connect main power cord to your wall outlet yet at this time C...

Страница 10: ...d insert in power supply box DO NOT plug power cord into your wall outlet until all electrical connections are complete inside of the sauna Connect circular connector for the door heater Ensure that t...

Страница 11: ...upply box Connect main power cord to your wall outlet when all electrical connections inside of the sauna and the roof are complete Chromatherapy The Chromatherapy LED panel is controlled by the remot...

Страница 12: ...ith strong magnets It is necessary to remove the heater guards from the two side walls in order to install the leg heater and the sauna bench Leg Heater Install the leg heater by lowering it into the...

Страница 13: ...ench The bench in your new sauna is reversible Choose whichever side appeals to you to face upward Reinstall the side wall heater guards Install the door handle Australia 1800 316 962 New Zealand 0800...

Страница 14: ...guards can be screwed directly to the wall for a more permanent and secure attachment The heater guards are pre drilled for the attachment screws Screws are included to attach the heater guard to the...

Страница 15: ...rill deeper than necessary for the length of the screw NOTE The pilot holes are important to ensure that the tongue and groove wall boards do not split when installing screws Install screws to firmly...

Страница 16: ...nch legs to the inside corners of the frames using supplied wood screws Attach the leg assembly to the bottom of the bench surface Choose which surface of the bench you prefer to be the top and bottom...

Страница 17: ...s by wiping sweat from your body regularly during your sauna session The floor heater can be used with or without a SMALL towel under your feet Sweat Always sit on a towel on the sauna bench and wipe...

Страница 18: ...aning Simply tilt the floor grate up to access the floor heater Gently wipe the heater with a damp cloth to clean A bit of dish soap can be used on the floor heater if necessary DO NOT scrub the heate...

Страница 19: ...utlet a beep will sound indicating the Audio circuit board in the roof has power The circuit board s colored LED indicator lights will flash and these will continue to flash whenever the sauna is plug...

Страница 20: ...ct your device to the sauna s audio system by inserting a 3 5 mm male to male audio cord into the BT circuit board as shown Audio cords not included To completely eliminate the RF Bluetooth signal sim...

Страница 21: ...Reinstall the roof panels and feed your audio cord through the hole in roof Enjoy your favorite audio while relaxing in your new sauna Australia 1800 316 962 New Zealand 0800 21 8020...

Страница 22: ...Control Panel Australia 1800 316 962 New Zealand 0800 21 8020...

Страница 23: ...Interior Control Panel Temperature Sensor FRAGILE DO NOT TOUCH Australia 1800 316 962 New Zealand 0800 21 8020...

Страница 24: ...OFF at any time by pushing the POWER button Timer Adjustment The default time is 60 minutes Press or to change the Timer setting The maximum setting is 60 minutes The minimum setting is 5 minutes Pre...

Страница 25: ...rior temperature is higher than the Thermostat set temperature the power to the heaters will be turned OFF The heater panels will begin to cool down air temperature and Infrared levels will slowly dro...

Страница 26: ...Stream Sauna comes equipped with backrests constructed from Western Red Cedar Position the backrest as pictured to provide lower back support and to position yourself a comfortable distance from the I...

Страница 27: ...Enjoy your new Sun Stream Evolve Infrared Sauna Australia 1800 316 962 New Zealand 0800 21 8020...

Отзывы: