1
This guide describes the minimum steps you must perform to power on Oracle’s Sun Netra X6270 M2 server
module for the first time.
Additional installation information is provided in the
Sun Netra X6270 M2 Server Module Installation
Guide
(821-0937) and in the installation guide for the modular system (chassis). This documentation is available
at the Sun documentation web site. See
“Documentation for This Product” on page 5
.
Note –
Before installing this server module, read the latest
Sun Netra X6270 M2 Server Module Product Notes
(820-2383) to find out if any late-breaking issues impact installation requirements.
▼
Install Optional Components
♦
Before installing the server into the modular system chassis, install any optional components that you
ordered with the server, such as storage drives, DIMMs, REMs, FEMs, and so on.
Refer to the online
Sun Netra X6270 M2 Server Module Installation Guide
.
▼
Install the Server Module
You can insert the server module into a chassis that is either powered on or not powered on. For information
about powering on the modular system chassis, refer to the modular system documentation.
The following procedure assumes the chassis is powered on.
1. Verify that the system chassis is powered on.
When the chassis is powered on, the fans are operating and the OK LED illuminates a steady on green light.
2. From the front of the chassis, locate and remove the filler panel from the slot where you plan to insert the
server module.
Pull the lever out and eject the filler panel.
3. Position the server module vertically with the ejectors extended and oriented on the right.
4. Push the server module into the slot until the server module stops and is even with the chassis.
Sun Netra X6270 M2 Server Module
Getting Started Guide