9-4
Sun Ultra 1 Series Service Manual—November 1995
9
9.1.2 Replacing a Disk Drive
Note –
If there are two drives, install the drives into their original slots. If the
drives are not installed in their original slots, the system may fail to boot, or
file systems may fail to mount.
1. With the drive handle open, press on the end of the drive to insert the
drive all the way into the chassis and connect it to the SCSI backplane.
See Figure 9-3.
Figure 9-3
Replacing the Disk Drive
2. Close the drive handle until the release latch clicks and the handle is
securely latched to the chassis.
See Figure 9-3.
Note –
The drive handle will not latch if the drive is not fully inserted into the
slot.
Drive handle
Disk drive
Chassis
Drive handle
Содержание Ultra 1 140
Страница 6: ......
Страница 8: ...Sun Ultra 1 Series Service Manual November 1995...
Страница 12: ...x Sun Ultra 1 Series Service Manual November 1995 Glossary Glossary 1 Index Index 1...
Страница 23: ...Part1 SystemInformation Product Description page 1 1...
Страница 24: ......
Страница 28: ...1 4 Sun Ultra 1 Series Service Manual November 1995 1...
Страница 30: ......
Страница 46: ...3 14 Sun Ultra 1 Series Service Manual November 1995 3...
Страница 62: ...4 16 Sun Ultra 1 Series Service Manual November 1995 4...
Страница 63: ...Part3 PreparingforService Safety and Tool Requirements page 5 1 Power On and Off page 6 1...
Страница 64: ......
Страница 68: ...5 4 Electron Service Manual November 1995 5...
Страница 72: ......
Страница 108: ...8 32 Sun Ultra 1 Series Service Manual November 1995 8...
Страница 121: ...Part5 SystemBoard System Board and Component Replacement page 10 1...
Страница 122: ......
Страница 147: ...Part6 IllustratedPartsBreakdown Replacement Parts page 11 1...
Страница 148: ......
Страница 152: ......
Страница 166: ...C 4 Sun Ultra 1 Series Service Manual November 1995 C...
Страница 170: ...Glossary 4 Sun Ultra 1 Series Service Manual November 1995...
Страница 174: ...Index 4 Sun Ultra 1 Series Service Manual November 1995...