background image

 

www.suntelecom.cn • 021-60138638 • [email protected]

 

English   

 

       

 

 

                                                         

 

   

 

 

User’s Manual 

SUN-LS100  Series 

 

 

 

 

 

 

 

 

Fiber Optic Light Source                                                       

 

 

 

 

 

 

 

 

 

 

Table:SUN-UM-TE-LS005                                                                                                                      Version:A/0

Содержание SUN-LS100 Series

Страница 1: ...www suntelecom cn 021 60138638 ics suntelecom cn English User s Manual SUN LS100 Series Fiber Optic Light Source Table SUN UM TE LS005 Version A 0 ...

Страница 2: ...n s P r o v i d e r ii www suntelecom cn 021 60138638 ics suntelecom cn Content 1 Overview 1 2 Specifications 1 3 Standard Accessories 2 4 Function 2 5 Operation 3 6 Maintenance 3 7 Troubleshooting 4 8 Notice 4 9 Warranty and service 5 ...

Страница 3: ...with high stability multi wavelength and single multi mode Large LCD display Switch button for changing operating wavelength and easy to operate Long working hours Standard FC port or customizable FC SC ST interchangeable port Auto power off after 10 minutes without operation Low battery voltage detection 2 Specifications Parameters Specification Wavelengths nm 850 1300 1310 1490 1550 1625 up to 4...

Страница 4: ...138638 ics suntelecom cn Dimensions mm 192 L x 102 W x 50 H Weight g 310 without battery 3 Standard Accessories No Product Unit Quantity 1 Light Source set 1 2 AA 1 5V Battery pieces 3 3 Soft Bag piece 1 4 Power Adapter piece 1 5 User s Manual piece 1 4 Function Function Instructions ...

Страница 5: ...r the continuous light mode 5 Operation 1 1 Turn on off the unit Press key to turn it on then the LCD screen display the following information 1 When using the AC adapter the AC adapter s mark will be showed on the central left screen and lighted 2 The battery mark is showed on the left bottom screen and will be lighted when using the battery The capacity in the mark will decrease with battery pow...

Страница 6: ...s Solution Faint display on the LCD screen The battery power is low Charge or replace the battery Fail to turn the unit on Low battery power or the battery is put wrongly Replace the battery Re put the battery Optical power is not stable after the unit turned off Use it after 15 minutes warm up 8 Notice Ensure the connector is clean when tested Do not plug in the power supply when install the batt...

Страница 7: ...ir or replace will not be higher than purchasing price of this unit 9 2 If the problems occurred can not be solved by the trouble shooting methods please contact us or the local distributor directly 9 3 This warranty is limited to defects in our production workmanship or material we will repair or replace the unit free of charge This warranty only applies to the unit under normal operation without...

Страница 8: ... TELECOMMUNICATION CO LTD Building No 145 Lane 666 Xianing Rd Jinshan Industrial Zone Jinshan District ShangHai China 201506 Tel 86 21 60138638 Fax 86 21 60138635 401 E mail ics suntelecom cn http www suntelecom cn ...

Отзывы: