70
Sun Fire X4150 Server Product Notes • February 2010
Issues Fixed in Tools and Drivers DVD Version 2.0
The following issues are fixed with Tools and Drivers CD version 2.0.
Setup Utility Error in CLI Mode (CR 6687003)
When using the StorageTek SAS controller setup utility in CLI Mode, the initial
menu is displayed and then "5;00H" is continuously scrolled so that the menu is
scrolled off the screen. This issue have been fixed in ILOM BIOS version 1ADQW052
or later.
Issues Fixed in Tools and Drivers CD Version 1.3.3
The following issues are fixed with Tools and Drivers CD version 1.3.3.
Cannot Use the Firmware Setup Utility for the SG-XPCIE SAS-R-INT-
Z HBA Card in ELOM Console (CR6687003)
The firmware setup utility for the SG-XPCIE SAS-R-INT-Z HBA card is unusable
through the ELOM console.
Workaround: Use the web GUI Remote Console redirection utility or a locally
attached keyboard and monitor setup to configure the disks so that the OS can be
installed and used.
CMOS Checksum Error Causes System to Wait for User to Press F1
(CR6786763)
When the CMOS checksum error occurs during POST, the POST halts until the user
presses F1.
With this firmware update, optimized defaults are loaded and POST continues when
the checksum error is encountered.
Wrong Slot Shown in
prtdiag
(CR6728704)
When you run the
prtdiag
command on a Solaris system when two cards are
installed in slot1 and slot0, the
prtdiag
reports that slot1 and slot2 are in use.