Chapter 2
Installing the Sun Fire T2000 Server
23
FIGURE 2-11
Mounting the Left Side of the Slide Rail
▼
To Verify the Operation of the Slide Rails and
the CMA
Tip –
Two people are needed this procedure: one to move the server in and out of
the rack and one to observe the cables and CMA.
1. For a cabinet or a free-standing rack, deploy the anti-tilt bar.
2. Unlock the slide lock buttons (
) at the right and lefts sides of the server
chassis, and slowly pull the server out of the rack until the slide rails reach their
stops.