Appendix B
Brocade Communications Systems Switch Troubleshooting
103
Troubleshooting Case Study
The following case study illustrates a practical application of the steps outlined
above. This is only one way to approach the problem; there may be others.
Note –
Knowledge and training on all components in a SAN are prerequisites
before you attempt the procedures below.
In this test case, the I/O load was generated using the
dex
disk exerciser to simulate
customer load, and the steps below allowed the I/O to continue uninterrupted
throughout the procedure.
Configuration
■
Sun Fire V880
■
Solaris 8 02/02 (Update 7) with all recommended and latest Sun StorEdge
Network Foundation Software patches
■
Sun StorEdge T3 array Partner Pair with FW 1.18
■
Brocade Silkworm 2400 and 2800 switches with v2.6.0 firmware
■
Storage Automated Diagnostic Environment version 2.1 with the latest patches
Note –
The Storage Automated Diagnostic Environment version 2.1 was configured
to send email alerts to a system administrator’s email address.
Содержание StorEdge
Страница 8: ...viii Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 18: ...xvi Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 26: ...8 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 48: ...30 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 55: ...Chapter 3 Diagnostics 37 FIGURE 3 4 Storage Automated Diagnostic Environment Test from Topology Window ...
Страница 82: ...64 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 131: ...Appendix B Brocade Communications Systems Switch Troubleshooting 113 FIGURE B 5 Test Result Details with Remedy Request ...
Страница 138: ...120 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 156: ...138 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 162: ...144 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...
Страница 168: ...150 Sun StorEdge SAN 4 0 Release Field Troubleshooting Guide October 2002 ...