19.0 A0h_Carousel Motion Failure
This error code indicates an error occurred during carousel movement (position not found). A missing or
misaligned cartridge, an obstruction or an unexpected cartridge in the carousel path can cause this error.
Troubleshooting should begin with cycling autoloader power.
DP1:
Check to see if the error code is still present after cycling autoloader power.
Note:
The autoloader power switch is located in the lower left corner of the front panel behind the bezel.
Use the eraser end of a pencil or something similar to press the right side of the power switch to toggle it to
the OFF position. Press the left side of the power switch to toggle it back to the ON position.
R1:
Error code is still present.
A1:
Toggle the front panel power switch to the OFF position.
A1:
Remove the AC power cord and SCSI cables from the back panel of the autoloader.
DP2:
Inspect the autoloader for stuck cartridges and/or misaligned cartridge carriers.
Note:
For instructions on removing stuck cartridges and inspecting for proper cartridge carrier
installation, refer to Sun StorEdge L8 Tape Autoloader User’s Guide (6-00522-01) ->
Troubleshooting and Diagnostics -> Removing Stuck Cartridges From Slots.
R2:
Stuck cartridges and/or misaligned carriers not found.
A2:
Remove all media.
A2:
Reinstall cartridge carriers, autoloader cover and power cord. Check to see that the
LVD SCSI terminator is securely installed.
A2:
Toggle the front panel power switch to the ON position.
DP3:
Check to see if the error code is still present.
R3:
Error code is still present.
A3:
Replace the autoloader.
R3:
Error code no longer present.
A3:
Import media, reconnect SCSI cables, and continue normal
autoloader operation.
R2:
Stuck cartridges and/or misaligned carriers found.
A2:
Remove stuck cartridges and reinstall cartridge carriers.
A2:
Reinstall autoloader cover and power cord. Check to see that the LVD SCSI
terminator is securely installed.
A2:
Continue normal autoloader operation.
R1:
Error code no longer present.
A1:
Continue normal autoloader operation.