3-8
Sun StorEdge D2 Array Installation, Operation, and Service Manual • February 2002
▼
To Find the Device Name of a Faulty Disk
Do this procedure to find the device name (c
w
t
x
d
y
) of the disk that failed. If needed,
see “Device Naming Conventions” on page 4-4.
1. If disk management software is being used on the host connected to the array, find
the device name of the failed disk by following the applicable procedure in the
documentation that came with the software.
Different applications provide various levels of error logging. In general, you can
find messages about failing or failed disks in your system’s console window.
2. If no disk management software is being used, find the device name of the failed
disk in
/var/adm/messages
.
Содержание StorEdge D2
Страница 10: ...x Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 50: ...2 12 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 92: ...4 28 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 98: ...B 2 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 104: ...B 8 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 114: ...B 18 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...
Страница 118: ...Index 4 Sun StorEdge D2 Array Installation Operation and Service Manual February 2002 ...