![Sun Microsystems StorEdge 3000 Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/sun-microsystems/storedge-3000-series/storedge-3000-series_installation-operation-and-service-manual_1392458029.webp)
Chapter 1
Product and Architecture Overview
1-3
For a list of supported racks and cabinets, refer to the release notes for the Sun
StorEdge 3510 FC array. You can find these release notes at:
http://www.sun.com/products-n-solutions/hardware/docs/
Network_Storage_Solutions/Workgroup/3510
Reliability, availability, and serviceability (RAS) are supported by:
■
Redundant components
■
Notification of failed components
■
Components that are replaceable while the unit is online
For information about specifications and agency approvals, see
FC Array Specifications” on page A-1
1.2
Field-Replaceable Units (FRUs)
This section describes the FRUs contained in the Sun StorEdge 3510 FC Array.
1.2.1
RAID I/O Controller Modules
A dual-controller configuration offers increased reliability and availability because it
eliminates a single point of failure, the controller. In a dual-controller configuration,
if the primary controller fails, the array automatically fails over to the second
controller without an interruption of data flow.
The Sun StorEdge 3510 FC Array I/O controller modules are hot-swappable. Each of
these RAID controller modules provides six Fibre Channel ports that support 2-
gigabit (Gb) or 1-Gb data rates. Single- and dual-controller models are available,
with the dual-controller version supporting active/passive and active/active
configurations. Each 3510 RAID controller is configured with 1 gigabyte (Gbyte) of
cache.
In the unlikely event of a failure, a redundant RAID controller immediately begins
servicing all I/O requests. The failure does not affect application programs.
* A disk array with no controller. Each expansion unit has two Fibre Channel loops that can provide redundant
data paths back to the RAID array.
† A disk array with no controller that is connected directly to a host computer, with no RAID array in the loop.
‡ The host-based Sun StorEdge Configuration Service software provides a graphical user interface (GUI) and ad-
ditional event-reporting capabilities.
Содержание StorEdge 3000 Series
Страница 14: ...xiv Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 18: ...xviii Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 38: ...1 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 48: ...2 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 54: ...3 6 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 140: ...5 62 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 180: ...7 32 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 208: ...8 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 242: ...B 28 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 247: ...Appendix D Record of Settings D 3 D 1 2 Logical Drive Partition Information LG Partition Size MB LG Partition Size MB ...
Страница 252: ...D 8 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 270: ...G 12 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 280: ...H 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...
Страница 312: ...K 10 Sun StorEdge 3000 Family Installation Operation and Service Manual March 2004 ...