70
Netra 240 Server Service Manual
• June
2004
Installing or Closing the Air Duct and Rear Fan
Assembly
1. Slide the air duct and rear fan assembly into position.
2. Plug in the two lower cables from the system board (
3. Rotate the assembly back in position and press down to snap the locking tab.
4. Close the rotating service module.
See
“Closing the Rotating Service Module” on page
.
5. Install the server cover.
See
“Installing the Server Cover” on page
6. Power on the server.
See
“Powering On the Server” on page
Memory Modules
There are eight DIMM slots on the system board, with four DIMM slots adjacent to
each CPU socket. Because memory is installed as matched DIMM pairs, these slots
are divided into two DIMM banks per CPU (see
Therefore, CPU0 has four corresponding DIMM slots divided into two banks, Bank0
and Bank1. CPU1 has four corresponding DIMM slots divided into two banks,
Bank0 and Bank1.
Содержание Netra 240
Страница 7: ...Contents vii Index 133...
Страница 8: ...viii Netra 240 Server Service Manual June 2004...
Страница 12: ...xii Netra 240 Server Service Manual June 2004...
Страница 70: ...52 Netra 240 Server Service Manual June 2004...
Страница 84: ...66 Netra 240 Server Service Manual June 2004...
Страница 120: ...102 Netra 240 Server Service Manual June 2004...
Страница 124: ...106 Netra 240 Server Service Manual June 2004...
Страница 132: ...114 Netra 240 Server Service Manual June 2004...