Sun Fire

V440 Server 2-Post

Rackmounting Guide

Part No. 817-0952-10
July 2003, Revision A

Содержание Fire V440 2-Post

Страница 1: ...4150 Network Circle Santa Clara CA 95054 U S A 650 960 1300 Submit comments about this document at http www sun com hwdocs feedback Sun Fire V440 Server 2 Post Rackmounting Guide Part No 817 0952 10...

Страница 2: ...VALID Copyright 2003 Sun Microsystems Inc 4150 Network Circle Santa Clara California 95054 Etats Unis Tous droits r serv s Sun Microsystems Inc a les droits de propri t intellectuels relatants la tech...

Страница 3: ...ounting and Setup Tasks 2 Inventory for 2 Post Rackmounting 3 Attach the Mounting Brackets to the Chassis 4 Locate the Mounting Holes 5 Install the Mounting Screws 6 Install the Server Into the Rack 7...

Страница 4: ...iv Sun Fire V440 Server 2 Post Rackmounting Guide July 2003...

Страница 5: ...are included in the Sun Fire V440 Server Installation Guide How This Book Is Organized This guide consists of a single chapter and replaces all rackmounting and cable management arm instructions in th...

Страница 6: ...ation Title Part Number Late breaking product information Sun Fire V440 Server Product Notes 816 7733 Cabling and power on overview Sun Fire V440 Server Setup Cabling and Power On 816 7734 System inst...

Страница 7: ...cumentation and welcomes your comments and suggestions You can submit your comments by going to http www sun com hwdocs feedback Please include the title and part number of your document with your fee...

Страница 8: ...viii Sun Fire V440 Server 2 Post Rackmounting Guide July 2003...

Страница 9: ...r from the rack to service any other component See the Sun Fire V440 Server Parts Installation and Removal Guide for more information This chapter contains the following procedures and information Che...

Страница 10: ...rver Installation Guide on your Documentation CD Begin with the section Install Optional Components in Chapter 2 TABLE 1 Overview of 2 Post Rackmounting and Setup Steps Step Task Refer To 1 Unpack the...

Страница 11: ...V440 server you intend to install into a rack You also need the Sun Fire V440 Server Installation Guide from the Documentation CD and the Rack Alignment template from the ship kit Tool Required Screwd...

Страница 12: ...4 Sun Fire V440 Server Installation Guide July 2003 Attach the Mounting Brackets to the Chassis Using three M4 screws for each bracket attach the mounting brackets to the chassis M4...

Страница 13: ...lignment template complete these steps a Place the Rack Alignment template over the vertical rack rail with the side marked for 2 post rack installation facing out b Place the Rack Alignment template...

Страница 14: ...2 screw on the left and one 10 32 x 1 2 screw on the right vertical rack rails Use the holes you marked in the previous step Do not fully tighten the screws until after you install the server Leave a...

Страница 15: ...mation about stabilizing the rack Caution The server is heavy Two persons are required to move the server 1 With one person on each side of the server lift the server and approach the rack with the ba...

Страница 16: ...s and the mounting screw on each side to secure the server to the vertical rack rails Install the Server Into a Populated Rack Attach the mounting brackets to the chassis using three M4 screws for eac...

Страница 17: ...re to support the weight of the server so that you do not damage the component installed below it in the rack 1 Slide the server into the open position in the rack Allow four rack unit spaces 7 0 inch...

Страница 18: ...uide July 2003 What Next The next steps are to connect the power cords and Ethernet cables and then to power on the server See the Sun Fire V440 Server Installation Guide beginning with the section In...