Power-On Self Test (POST)
User Guide—Sun Cobalt LX50 Server
6-7
Power-On Self Test (POST)
During the power-on self test (POST), the server may indicate a system fault by:
•
Displaying error codes and messages at the display screen
•
Beeping the speaker in a coded sequence
•
Illuminating the POST LEDs, visible from the rear panel, in a coded fashion
POST Screen Messages
During POST, if an error is detected, the BIOS displays an error code and message to the screen. The following tables
define POST error codes and their associated messages. The BIOS prompts the user to press a key in case of serious
errors. Some of the error messages are preceded by the string “Error” to highlight the fact that the system may be
malfunctioning. All POST errors and warnings are logged in the System Event Log (SEL). See “Managing the
System Event Log” on page 4-14 for more details on the SEL
✍
Note:
All POST errors are logged to the SEL, which is capable of holding over 400 entries.
After the SEL is full, no further errors are logged.
Table 12.
Standard POST Error Messages and Codes
Error
Code
Error Message
Pause On Boot
100
Timer Channel 2 Error
Yes
101
Master Interrupt Controller
Yes
102
Slave Interrupt Controller
Yes
103
CMOS Battery Failure
Yes
104
CMOS Options not Set
Yes
105
CMOS Checksum Failure
Yes
106
CMOS Display Error
Yes
107
Insert Key Pressed
Yes
108
Keyboard Locked Message
Yes
109
Keyboard Stuck Key
Yes
10A
Keyboard Interface Error
Yes
10B
System Memory Size Error
Yes
10E
External Cache Failure
Yes
110
Floppy Controller Error
Yes
111
Floppy A: Error
Yes
112
Floppy B: Error
Yes
113
Hard disk 0 Error
Yes
Содержание Cobalt LX50
Страница 1: ...Sun Cobalt LX50 Server User Guide...
Страница 10: ...Contents x User Guide Sun Cobalt LX50 Server...
Страница 14: ...xiv User Guide Sun Cobalt LX50 Server...
Страница 22: ...Chapter 1 Introducing the Sun Cobalt LX50 server 1 8 User Guide Sun Cobalt LX50 Server...
Страница 58: ...Chapter 3 Controls and Indicators 3 4 User Guide Sun Cobalt LX50 Server...
Страница 79: ...Using the Service Partition Menu User Guide Sun Cobalt LX50 Server 4 21 Figure 58 Sample RESULT LOG continued...
Страница 114: ...Chapter 5 Maintaining the Server 5 30 User Guide Sun Cobalt LX50 Server...
Страница 132: ...Chapter 6 Troubleshooting the Server 6 18 User Guide Sun Cobalt LX50 Server...