Sun Gold Power Co.,Ltd
www.
sungoldpower.com
32
8. Technical Parameter
Model
SPH504880A
AC mode
Rated input voltage
110/120Vac
Input voltage range
(90Vac-140Vac)
Frequency
50Hz/ 60Hz (auto-sensing)
Frequency range
47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Overload/short- circuit protection
Breaker
Efficiency
>95%
Conversion time
10ms (Typical value)
(Bypass and inverting)
AC reverse flowing protection
yes
Maximum bypass overload current
63A
Inverting mode
Output voltage waveform
Pure sine wave
Rated output power (VA)
5000(4100/ 4300/4500)
Rated output power (W)
5000(4100/ 4300/4500)
Power factor
1
Rated output voltage (Vac)
120Vac (100/105/110Vac Settable)
Output voltage error
±5%
Output frequency range (Hz)
50Hz ± 0.3Hz /60Hz ± 0.3Hz
Efficiency
>90%
Overload protection
(102%<lo
ad<110%) ±10%: reporting error
and turn off the output after 5 minutes;
(110%<lo
ad<125%) ±10%: reporting error
and turn off the output after 10 seconds
;Load>125% ±10%: reporting error and turn off the
output after 5 seconds;
Peak power
10000VA
Loaded motor capacity
4HP
Output short-circuit protection
Breaker
Specification of bypass breaker
63A
Rated battery input voltage
48V (minimum start voltage 44V)
Battery voltage range
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm/turnoff
voltage/overvoltage
alarm/overvoltage restoration…settable LCD screen)
Power saving mode
Load ≤50W
AC charge
Battery type
Lead acid or lithium battery