Sumo UK Ltd
Redgates
Melbourne
York
YO42 4RG
Tel. 01759 319900
Fax. 01759 319901
Quick Start Guide
1.0 Set Implement Width
1.
Select the Area Total channel (
).
2.
Press and hold the
button for 5 seconds. The display will flash "
tot.1
",
then "
tot.2
" then shows the programmed implement width (fig. 1).
Default width = 4 metres.
3.
Continue holding the
button and PRESS
to select the digit/decimal
point to change.
4.
HOLD
to change the digit (or move the decimal point). Releasing the
button selects the next digit (fig. 2).
5.
Release the
button to return to the normal display mode.
2.0 Changing the Target Rate
When the drilling rate is currently at the target rate:-
1.
With the rate display selected,
press and hold
either the
button or the
button for
5 seconds
(fig. 4) until the number is flashing, then release.
2.
Press either the
button to increase the target rate
(KG/Ha),
or the
button to decrease the target rate
(KG/Ha)
(fig. 4). The longer the button is
held, the faster the number changes. Release the button.
3.
When the desired target rate
(KG/Ha)
is displayed,
press and hold
the
button. The instrument will beep
5 times
and the display will alternate
between the set rate and the calculated minimum forward speed for that rate.
After 5 seconds the instrument will display ‘
done
’ after which the button can
be released to return to normal operating mode.
Figure 2: Change
Implement Width
Figure 1: View
Implement Width
Figure 4: Adjust Target
Rate
Figure 3: View current
Target Rate