15
OWNER’S MANUAL
Should you encounter any problems, contact Customer Service at (888) 919-0070 from 8AM to 5PM MST, Monday-Friday.
Extended operating days and hours during peak season requirements.
1. Loosen the Volute Cover Lock Nut or Bolts & Nuts (depends on the pump model), and remove the Volute Cover .
2. Pull the Rotor Assembly out from the Pump Body .
3. Inspect the Rotor (see image below) to make sure that the Rotor Shaft, Magnet Axle, Impeller and other parts are intact. If either of them is broken, you
can purchase a new Rotor Assembly from polygroupstore.com without having to replace the whole Pump.
For more details, please see Pool Support – Filtration System Troubleshooting – RX System at support.polygroupstore.com
24
25
23
22
21
4. Once the inspection or replacement is done, carefully insert the Rotor Assembly back into the Pump Body. The force of the magnet will pull the Rotor down in place.
5. Align the Volute Cover with the top End Cap of the Rotor, then tighten with the Volute Cover Lock Nut or Bolts & Nuts (depends on the pump model).
6. Attach the Rubber Nozzle to the outlet of the Motor Assembly.
1. Lubricate the Canister Gasket , then insert it back into the groove
at the bottom of the Canister .
2. Place the cord of the Motor Assembly through the Pump Base .
STEP 3: Pump Replacement/Reassembly
18
16
19
15
17
RX1500
25
23
22
21
RX600/RX1000
24
23
22
21
Rotor Assembly Parts
Shaft End Cap
Washer
Impeller
Magnet Axle
Rotor Shaft
(This shaft should go through
all the parts and into both
Shaft End Caps)
Washer
Shaft End Cap
Step 1
Step 2
16
15
Cord
STEP 2: Rotor Inspection/Replacement
19