background image

LYNX2

LYNX2--MPO for Round Cord with 12 or 8 Individual Fibers

MPO for Round Cord with 12 or 8 Individual Fibers

Assembly

Assembly Procedure

Procedure

ETK1123092D

(A) Set Fusion Condition

(B) Perform Arc Test

See the operation manual of T-71M12.

(1) Slide Rear Parts onto
the cord.

(2) Mark at 150mm from the end
of the cord.

(3) Mark Slit by LYNX2-CORDTOOL-2&3.

Set the cord on “3mm” groove.

Set the marking point 

at the edge of top

(4) Fold the slit outer sheath and Kevlar
backward. Hold them by a mending tape.

CH1

CH2

CH3

CH4

CH5

CH6

CH7

CH8

CH9 CH10 CH11 CH12

Method A

End A

BL

OR

GR

BR

SL

WH

RD

BK

YL

VI

PK

AQ

End B

BL

OR

GR

BR

SL

WH

RD

BK

YL

VI

PK

AQ

Method B

End A

BL

OR

GR

BR

SL

WH

RD

BK

YL

VI

PK

AQ

End B

AQ

PK

VI

YL

BK

RD

WH

SL

BR

GR

OR

BL

Method C

End A

BL

OR

GR

BR

SL

WH

RD

BK

YL

VI

PK

AQ

End B

OR

BL

BR

GR

WH

SL

BK

RD

VI

YL

AQ

PK

Another

(ex. Corning)

End A

BL

OR

GR

BR

SL

WH

RD

BK

YL

VI

PK

AQ

End B

AQ

PK

VI

YL

BK

RD

WH

SL

BR

GR

OR

BL

Table 1. Fiber Alignment. (See Appendix.)

(5) Fiber standing in line according to Table 1.

The way to align the order in hand

every 4 fiber might be easy.

Push “power

key” for more

than 1 sec.

Arc Test “ON”.

Then perform the arc test
according to the instruction.
*Fiber for testing is included 
in the kit. 
Please check fiber type 
inside the field fiber.

“Main Menu”

Select Fiber Type

Select “Fiber Type”, then “Return”.

“Main Manu”

Select Sleeve Type

Select Sleeve Type

Then “Return”

For 8c

For 12c

Copyright © 2011 Sumitomo Electric Industries, LTD.

(9) Set ribbon fiber on Fiber holder.

(10) Remove Coating (JR-6)

1. Place

3. Slide

Clean rubber clamp 
and blade regularly

(12) Cleave the fiber (FC-6M)

No gap

(13) Set fiber holder on the splicer 
(left side).

2. Close

Place fiber on 

V-groove gently

Spring

(Remove from

Front Parts)

Protection

Sleeve

CH1 Fiber

Front Side

Stainless Steel

Bottom Side

Make sure the

orientation of Sleeve

CH1 Fiber

Front Side

25mm

(11) Fiber Cleaning.

Moistened 

with alcohol

(8) Slide Rear Parts, Spring and Protection

Sleeve onto the ribbon fiber.

(6) Ribbon Processing.

1. Apply Adhesive

2. Put an adhesion department with a 

sponge

3. Move a slide stage

No Bending

No gap between fibers

4. Completion

130mm

>30mm

(7) Cut the fiber to be 130mm and confirm the

length of ribbonized is 30mm or more.

every 4 fiber might be easy.

Ribbon End

Marking

Marking