Connect the suction hose
Procedure
1. Connect the suction hose (A) to the
nipple (B).
Turn the nut (C) clockwise to tighten
the return hose to the oil outlet.
2. If applicable, put the drained oil back in
the gear unit or the hydraulic system.
Connect the return hose to the gear unit or the hydraulic system
Warning: The return hose must be pressure-free before you connect the
device to a gear unit or a hydraulic system. If the return hose is not pressure-
free, injury or damage to the device can occur.
Note: A connection set is required to connect the return hose. For information,
refer to section
Install the connection part
Procedure
1. Remove the filling plug or breather
from the gear unit or the hydraulic
system. Keep the filling plug for re-
installation.
2. Install the connection part (A) and the
seal (B) in the hole of the filling plug.
Use a torque wrench to torque the
connection part to the correct value.
For the torque values for the different
connection parts, refer to section
Torque values for the connection set
on page 31.
C
A
B
6.3.4
A
B
Installation
UM_VP2500L_002_EN
21
Содержание VP2500L
Страница 1: ...User Manual VP2500L Hansen Industrial Transmissions nv UM_VP2500L ...
Страница 34: ...Services 34 UM_VP2500L_002_EN ...