47
MAINTENANCE
6.2
GENERAL MAINTENANCE SAFETY
WARNING!
Never assume a compressor is safe to work on just because it is not operating. It could restart at any time.
WARNING!
Do not allow oil to accumulate on, in or around acoustic noise material. Immediately replace any oil-
soaked material after cleaning enclosure surface with nonflammable solvent.
WARNING!
Do not substitute bolts with material or markings different from the original equipment.
CAUTION!
Do not over-tighten any bolt, nut fitting, connection or spin-on filter element.
CAUTION!
Perform repairs and maintenance only in clean, dry conditions in a well-lit and ventilated area.
CAUTION!
Clean up any spilled oil or oil leakage and repair oil leaks as soon as they are discovered.
6.3
STOPPING FOR MAINTENANCE
The following procedures should be followed before doing any maintenance on the compressor and will not
be repeated in any of the maintenance procedures.
1.
Per Occupational Safety & Health Administration (OSHA) regulation 1910.147: The Control of Hazardous
Energy Source (Lockout/Tagout), disconnect and lockout the main power source. Display a sign in clear
view at the main power switch stating that the compressor is being serviced.
2.
Isolate the compressor from the compressed air supply by closing a manual shutoff valve downstream
from the compressor. Display a sign in clear view at the shutoff valve that the compressor is being
serviced. Be certain that a pressure relief valve is installed upstream of any isolation valve.
3.
Wait until sump pressure reading is 0 psig.
4.
Open all manual drain valves within the area to be serviced.
5.
Wait for the unit to cool before starting to service. Temperatures of 125°F (52°C) can burn skin. Some
surface temperatures exceed 250°F (121°C) when the compressor is operating and just after it is shut
down.
6.4
bOLT TORQUE GUIDELINES
6.4.1 INCH FASTENERS
Inch Fasteners Torque
Size
SAE Grade 5 (ft-lb)
SAE Grade 8 (ft-lb)
Dry
Oiled
Dry
Oiled
1
⁄
4
–20
8
6
12
9
5
⁄
16
–18
17
13
25
18
3
⁄
8
–16
30
23
45
35
7
⁄
16
–14
50
35
70
55
1
⁄
2
–13
75
55
110
80
9
⁄
16
–12
110
80
150
110
5
⁄
8
–11
150
110
220
170
3
⁄
4
–10
260
200
380
280
6.4.2 BOLT TORQUE FACTORS
Lubricant or Plating
Torque Changes
Oil
Reduce torque 15% to 25%
Dry film (Teflon or moly based)
Reduce torque 50%
Dry wax (Cetyl alcohol)
Reduce torque 50%
Chrome plating
No change
Cadmium plating
Reduce torque 25%
Zinc plating
Reduce torque 15%
6.4.3 BOLT TORQUE STAGES
Stage
Torque
1st
20-25 ft/lbs
2nd
55-60 ft/lbs
3rd
85-95 ft/lbs
Содержание 15D
Страница 6: ...vi About This Manual ...
Страница 12: ...4 Introduction ...
Страница 20: ...12 Specifications 2 2 DIMENSIONS OPEN BASE MOUNT AIR COOLED Figure 2 1 GA 15 40D AC BM OPEN ...
Страница 21: ...13 Specifications 2 3 DIMENSIONS ENCLOSED BASE MOUNT AIR COOLED Figure 2 2 GA 15 40D AC BM VERT ENCL ...
Страница 22: ...14 Specifications 2 4 DIMENSIONS OPEN BASE MOUNT WATER COOLED Figure 2 3 GA 15D 30D WC BM HORZ OPEN GAUGES ...
Страница 23: ...15 Specifications 2 5 DIMENSIONS ENCLOSED BASE MOUNT WATER COOLED Figure 2 4 GA 15 40D WC BM ENCL GAUGES ...
Страница 24: ...16 Specifications 2 6 DIMENSIONS OPEN PLATFORM MOUNT AIR COOLED Figure 2 5 GA 15 40D AC PLAT OPEN GAUGES ...
Страница 25: ...17 Specifications 2 7 DIMENSIONS ENCLOSED PLATFORM MOUNT AIR COOLED Figure 2 6 GA 15 40D AC PM VERT ENCL ...
Страница 30: ...22 Specifications 2 12 PIPING AND INSTRUMENTATION AIR COOLED Figure 2 11 GA P I S R02 ...
Страница 31: ...23 Specifications 2 13 PIPING AND INSTRUMENTATION WATER COOLED Figure 2 12 P I 15 40 WC GAUGES R00 ...
Страница 34: ...26 Specifications ...
Страница 66: ...58 Troubleshooting ...
Страница 84: ...76 Parts Catalog 8 10 AIR INLET ASSEMBLY 15 30HP 13 12 11 13 12 4 5 2 3 14 1 Figure 8 6 AS805 030D7H TE R00 ...
Страница 88: ...80 Parts Catalog 8 12 AIR INLET ASSEMBLY 40HP 14 15 5 15 4 3 2 13 1 Figure 8 8 AS805 040DS TE REV 00 ...
Страница 112: ...NOTES ...
Страница 113: ...NOTES ...