S
HOP
T
EK
™
USER MANUAL
SECTION 4
50
02250180-090 R00
O
UTDOOR
I
NSTALLATION
(S
HELTERED
)
ShopTek packages are equipped with TEFC motors
and have water tight controls that are NEMA 4 rated
and are suitable for sheltered outdoor installation.
The compressor should be mounted on a concrete
pad. If the pad is not level, the compressor must be
mounted in such a manner that its base or skid is
level in relation to the pad’s surface and fully
supported.
If the compressor will be exposed to blowing rain or
snow, it should be housed in a covered, four-walled
enclosure.
• Sheltered air-cooled machines must have
their exhaust air vented outside of the
enclosure.
• Installations consisting of more than one
compressor should be done in such a man-
ner that each compressor’s exhaust is
directed away from the air intakes of other
compressors or air dryers.
• A standard compressor should not be
started if the ambient temperature is 35°F
(1.7°C) or lower.
Compressor must not be operated in sub-
freezing conditions.
Figure 4-1: ST400, ST500, ST700 Shipping Strap
1. Shipping Strap
Table 4-1: Ventilation Requirements
Model
Ventilation Air Required
cfm
m
3
/hr
ST400
612
1040
ST500
612
1040
ST700
612
1040
ST1100
1471
2500
ST1500
1471
2500
Содержание ShopTek ST1100
Страница 10: ...NOTES 8...
Страница 22: ...NOTES 20 02250180 090 R00...
Страница 39: ...NOTES 37 02250180 090 R00...
Страница 48: ...S HOP T EK USER MANUAL SECTION 3 46 02250180 090 R00 Figure 3 14 Wiring Diagram SRS 25 100 115 230V 1 60...
Страница 49: ...SECTION 3 S HOP T EK USER MANUAL 47 02250180 090 R00 Figure 3 15 Wiring Diagram SRS 9 18 220 240V 1 50...
Страница 50: ...S HOP T EK USER MANUAL SECTION 3 48 02250180 090 R00 Figure 3 16 Wiring Diagram SRS 24 30 220 240V 1 50...
Страница 58: ...NOTES 56 02250180 090 R00...
Страница 71: ...NOTES 69...