2: Description

3000PB, 3700B, 4500B, 3000PVB, 3700VB, 4500VB User Manual

02250216-786 R01

18

Subject to EAR, ECCN EAR99 and related export control restrictions.

2.8

Variable speed drive (VSD) 
components

The VSD, located in the machine’s electrical enclosure, 
works in concert with the controller to allow the compres-
sor to match its output to the current demand of the sys-
tem. The drive’s heat sink extends through the back of 
the enclosure, and its cooled by air flowing through the 
compressor enclosure.

2.9

VSD control system, functional 
description

Refer to 

Figure 2-5

. The controls consist of:

• a VSD
• a solenoid valve
• a regulating valve
• an inlet valve

Depending on the model, a compressor can be operated 
at a setpoint pressure from 60 to 175 psig (4.1 to 
12.1 bar). The controller automatically sets the frequency 
range based on the selected pressure. (The compres-
sor's operating range is on its nameplate.)

The following paragraphs apply to a compressor with a 
100 psig (6.9 bar) operating pressure and a 6 psi 
(0.4 bar) load delta setting.

Compressors with different pressure operating ranges 
perform in the same manner.

Start mode—0 to 50 psig (0 to 3.5 bar)

Pressing the controller 

 (Start) pad signals the VSD 

to accelerate the motor to full speed, causing the separa-
tor/sump tank pressure to rise from 0 to 50 psig (0 to 
3.4 bar). At this time both the pressure regulator and 
solenoid valves are closed; the inlet valve is fully open 
and the air-end provides a full flow to the separator/sump 
tank. A minimum pressure valve set at approximately 
50 psig (3.4 bar) isolates the rising compressor air pres-
sure from the service line. 

Full load mode—50 to 100 psig (3.4 to 6.9 bar)

When the compressed air pressure rises above 50 psig 
(3.4 bar) the minimum pressure valve opens allowing 

compressed air to flow into to the service line. From this 
point on the controller monitors the line pressure which 
controls the VSD. The pressure regulator and solenoid 
valves remain closed with the inlet valve fully open, run-
ning at 100 psig (6.9 bar) or lower.

VSD part load control

The service line pressure increases to a value above 
100 psig (6.9 bar) if the demand is less than the com-
pressor's rated capacity. In this condition, the VSD slows 
the motor's rpm which reduces the output to match the 
demand. The drive continuously adjusts the motor's rpm 
to maintain a 100 psig (6.9 bar) line pressure.The con-
troller maintains the correct frequency when the VSD is 
operating in this mode.

Modulating mode—100 to 106 psig (7.3 to 6.9 bar)

During low demand periods and with the VSD running at 
minimum speed, the line pressure can continue to rise. 
When the line pressure reaches 101 – 102 psig (approxi-
mately 7 bar), the regulator valve (

Figure 2-5

) gradually 

opens, directing air pressure to the inlet control valve pis-
ton. This action causes the inlet valve to partially close, 
thereby reducing the air flow entering the compressor 
until it matches the demand. The control system func-
tions continuously in this manner between less than 
101 psig (7.0 bar) to 106 psig (7.3 bar), in response to 
varying system demand. The pressure regulator has an 
orifice which vents a small amount of air to the atmo-
sphere when the pressure regulator controls the inlet 
valve. The orifice also bleeds off any accumulated mois-
ture from the control line. When the discharge pressure 
rises above 106 psig (7.3 bar), or to a preset unload 
pressure, the compressor unloads.

Unload mode—in excess of 106 psig (7.3 bar)

When there is no demand or it is at a minimal level, the 
service line pressure continues to rise. When it exceeds 
106 psig (7.3 bar), or reaches a preset unload pressure 
value, the WS control system de energizes the solenoid 
valve allowing separator/ sump tank air pressure to be 
supplied directly which closes the inlet valve. The sole-
noid valve simultaneously sends a pneumatic signal to 
the blow down valve which opens to the atmosphere, and 
reduces the separator/sump tank pressure. The check 
valve in the air service line prevents line pressure from 
back-flowing to the separator/sump tank. The compres-
sor will shut down after the programmed unload time set-
ting expires (the default setting is zero (0) minutes for an 
immediate shutdown upon unload). When the line pres-
sure drops to the low pressure setting of 100 psig 
(6.9 bar) the controller starts the motor and energizes the 
solenoid valve which closes the blowdown valve. The re-

 NOTE

The load delta default setting is 10 psi (0.7 bar). 
Sullair recommends a setting of 6 psi (0.4 bar) 
for the most efficient operation.

Содержание 3000PB

Страница 1: ...r 201505080000 and all subsequent serial numbers USER MANUAL Publication date 6 17 2015 Copyright 2015 Sullair LLC All rights reserved WARRANTY NOTICE Failure to follow the instructions and procedures...

Страница 2: ...ncludes training on the function and installation of Sullair service parts troubleshooting common faults and malfunctions and actual equipment operation These seminars are recommended for maintenance...

Страница 3: ...n 9 2 1 Introduction 9 2 2 Description of components 9 2 3 Sullair compressor unit functional description 9 2 4 Compressor cooling and lubrication system functional description 12 2 5 Compressor disch...

Страница 4: ...Air cooled compressors 43 4 2 2 Water cooled compressors 43 4 2 3 Water system venting 44 4 2 4 Draining the water system 44 4 2 5 Water quality recommendations 45 4 2 6 Seawater cooled units 45 4 3 O...

Страница 5: ...nce 56 6 7 1 Air filter element replacement 56 6 8 Separator maintenance 57 6 8 1 Separator element replacement 57 6 9 Oil return sight glass maintenance 58 6 10 Pressure regulator adjustment 58 6 11...

Страница 6: ...Table of Contents 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 iv Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 7: ...e applicable to most compressors and the concepts behind these state ments are generally applicable to all compressors 1 2 Personal protective equipment A Prior to installing or operating the compress...

Страница 8: ...aterial or on any external surfaces of the air compressor Wipe down using an aqueous industrial cleaner or steam clean as required If necessary remove acoustical mate rial clean all surfaces and then...

Страница 9: ...DO NOT discharge air from these systems into unventilated or other confined areas C Operate the compressor only in open or adequately ventilated areas D Locate the compressor or provide a remote inle...

Страница 10: ...with a lifting bail then lift by the bail provided If no bail is provided then lift by sling Compressors to be air lifted by helicopter must not be supported by the lifting bail but by slings instead...

Страница 11: ...e work except when motion is necessary during setup adjustment or trouble shooting A The established procedures for the application of energy control shall cover the following elements and actions and...

Страница 12: ...motor drives These cautions that apply to VSD operation WARNING Ground the unit following the instructions in this manual Ungrounded units may cause electric shock and or fire The variable speed drive...

Страница 13: ...o not touch any components on the circuit boards Static voltage discharge may damage the components CAUTION Install the variable speed drive in a well venti lated room that is not subject to temperatu...

Страница 14: ...1 Safety 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 8 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 15: ...cooled versions have easily accessible items such as the fluid filter air oil separator and control valves The inlet air filter is also easily acces sible for servicing 2 3 Sullair compressor unit fun...

Страница 16: ...and related export control restrictions Figure 2 1 Overall component layout air cooled model 1 Fluid filter 8 E Stop button 2 Moisture separator 9 Compressor unit 3 Separator sump tank 10 Cooler fan...

Страница 17: ...export control restrictions 11 Figure 2 2 Overall component layout water cooled model 1 Moisture separator 8 E Stop button 2 Fluid filter 9 Compressor unit 3 Separator sump tank 10 Oil cooler 4 Fluid...

Страница 18: ...the com bination separator sump tank The separator sump has three basic functions It acts as a primary fluid separator Serves as the compressor fluid sump Houses the final fluid separator The compress...

Страница 19: ...700B 4500B 3000PVB 3700VB 4500VB User Manual 2 Description 02250216 786 R01 Subject to EAR ECCN EAR99 and related export control restrictions 13 Figure 2 3 Air cooled cooling lubrication and discharge...

Страница 20: ...tion 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 14 Subject to EAR ECCN EAR99 and related export control restrictions Figure 2 4 Water cooled cooling lubrication and discharg...

Страница 21: ...ice line The integrated inlet valve has an orifice which vents a small amount of air to the compressor inlet when the pressure regulator controls the inlet control valve The orifice also bleeds any ac...

Страница 22: ...16 Subject to EAR ECCN EAR99 and related export control restrictions Figure 2 5 Standard pneumatic control system 1 Air outlet 5 Blowdown valve 2 Unload solenoid valve 6 Minimum pressure check valve...

Страница 23: ...to the compressor in response to the operation of the pressure regulator Refer to Section on page 15 The inlet valve also acts as a check valve thus preventing reverse rotation when the compressor is...

Страница 24: ...essor s rated capacity In this condition the VSD slows the motor s rpm which reduces the output to match the demand The drive continuously adjusts the motor s rpm to maintain a 100 psig 6 9 bar line p...

Страница 25: ...n 02250216 786 R01 Subject to EAR ECCN EAR99 and related export control restrictions 19 energized solenoid valve prevents line pressure from reaching the inlet control valve thereby allowing it to ful...

Страница 26: ...2 Description 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 20 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 27: ...1712 35 108 62 1564 2055 2079 932 943 3700B series 3707B 50 67 1712 35 108 62 1564 2080 2120 943 962 3709B 50 67 1712 35 108 62 1564 2080 2120 943 962 3710B 50 67 1712 35 108 62 1564 2080 2120 943 962...

Страница 28: ...B through 3712VB 1 ODP 230 60 169 2030 921 67 1712 35 108 62 1564 460 60 72 2030 921 67 1712 35 108 62 1564 575 60 62 2030 921 67 1712 35 108 62 1564 TEFC 230 60 169 2070 939 67 1712 35 108 62 1564 46...

Страница 29: ...ompressors are available for operation in higher ambient temperature Motor Standard models Size 40 50 60 hp 30 37 45 kW Type C flanged open drip proof premium efficiency three phase 230 460 60 Hz VSD...

Страница 30: ...if condi tions warrant use of extended life lubricants contact Sul lair for recommendation 3 6 Application guide Sullair encourages the user to participate in a fluid analy sis program with the fluid...

Страница 31: ...I D SRF 1 4000 3 5 gal 13 2 L B E G C B D 24KT 3 5 gal 13 2 L F E G C I D PristineFG 3 5 gal 13 2 L H E G C B D A 10 000 hours or once a year B 4 000 hours or more frequently if conditions so require...

Страница 32: ...Specifications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 26 Subject to EAR ECCN EAR99 and related export control restrictions 3 8 Identification air cooled 02250216 524 R0...

Страница 33: ...S MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR 2 A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING THE WEIGHT OF PACKAGE AND RIGID ENOUGH TO MAINTAIN THE COMPRESSOR FRAME LEVEL...

Страница 34: ...Specifications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 28 Subject to EAR ECCN EAR99 and related export control restrictions 3 9 Identification water cooled 02250216 528 R...

Страница 35: ...kg 730 TEFC 2354 LBS 1068 kg 730 Drawing notes 1 ALLOW 4 00 FEET 1 25 METERS MINIMUM CLEARANCE AROUND MACHINE FOR ACCESS AND FREE CIRCULATION OF AIR 2 A FOUNDATION OR MOUNTING CAPABLE OF SUPPORTING T...

Страница 36: ...ications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 30 Subject to EAR ECCN EAR99 and related export control restrictions 3 10 Piping and instrumentation air cooled 02250216...

Страница 37: ...LVE DR 1 23 VALVE SOLENOID 2 24 VALVE PRESSURE REG 1 25 ELEMENT SEPARATOR 1 26 GAUGE DIFF PRESS 1 27 VALVE CHECK 3 28 VALVE BALL STNR COMBO 1 29 DRAIN ZERO LOSS 1 30 VENTILATOR ENCL 1 31 STRAINER V TY...

Страница 38: ...fications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 32 Subject to EAR ECCN EAR99 and related export control restrictions 3 11 Piping instrumentation water cooled 02250216 6...

Страница 39: ...RESSURE REG 1 25 TANK SEPARATOR 1 26 DRAIN ZERO LOSS 1 27 VALVE CHECK 2 28 HEAT EXCHANGER 1 29 SWITCH PRESS 1 30 VALVE WATER 1 31 VALVE SOLENOID 1 32 VALVE BALL STNR COMBO 1 33 STRAINER V TYPE 1 Drawi...

Страница 40: ...ecifications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 34 Subject to EAR ECCN EAR99 and related export control restrictions 3 12 Wiring diagram air cooled MFV 02250211 276...

Страница 41: ...L RUN RELAY CONTACT K2 INTERNAL Y DELTA START RELAY K3 INTERNAL WYE DELTA RUN RELAY K4 INTERNAL LOAD CONTROL RELAY K5 INTERNAL SEQUENCE RELAY K6 INTERNAL ELECTRIC DRAIN RELAY K7 INTERNAL COMMON FAULT...

Страница 42: ...3 Specifications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 36 Subject to EAR ECCN EAR99 and related export control restrictions 3 13 Wiring diagram YD 02250214 098 R03...

Страница 43: ...INTERNAL WYE DELTA RUN RELAY K4 INTERNAL LOAD CONTROL RELAY K5 INTERNAL SEQUENCE RELAY K6 INTERNAL ELECTRIC DRAIN RELAY K7 INTERNAL COMMON FAULT RELAY PF CAP POWER FACTOR CORRECTION CAPACITOR OPT L H...

Страница 44: ...000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 38 Subject to EAR ECCN EAR99 and related export control restrictions 3 14 Wiring diagram VSD air cooled parallel wye A1000 460V onl...

Страница 45: ...L Y DELTA START RELAY COMPRESSOR RUNNING K3 INTERNAL WYE DELTA RUN RELAY COMPRESSOR ENABLED K4 INTERNAL LOAD CONTROL RELAY K5 INTERNAL SEQUENCE RELAY K6 INTERNAL ELECTRIC DRAIN RELAY K7 INTERNAL COMMO...

Страница 46: ...0PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual 02250216 786 R01 40 Subject to EAR ECCN EAR99 and related export control restrictions 3 15 Wiring diagram VSD air cooled series delta A1000 230 575V o...

Страница 47: ...NAL Y DELTA START RELAY COMPRESSOR RUNNING K3 INTERNAL WYE DELTA RUN RELAY COMPRESSOR ENABLED K4 INTERNAL LOAD CONTROL RELAY K5 INTERNAL SEQUENCE RELAY K6 INTERNAL ELECTRIC DRAIN RELAY K7 INTERNAL COM...

Страница 48: ...3 Specifications 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 42 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 49: ...h adequate space must be provided for the compressor and its components Air cooled compressors require a minimum of 4 feet 1 25 meters around the perimeter of the compressor The location should be fre...

Страница 50: ...ce in utilizing this heat If ductwork is added the high static fan option is required Do not install a water cooled or an air cooled after cooled compressor where it will be exposed to tempera tures l...

Страница 51: ...h water treatment 4 2 5 2 Corrosion As contrasted to lime scale build up corrosion eventually causes a reduction in the wall thickness of pipes High levels of dissolved oxygen and low pH levels assist...

Страница 52: ...local weather conditions can be extreme such that direct rain or snow may fall on the unit it should be in a fully enclosed room or building If installed under a shelter air cooled machines must be po...

Страница 53: ...tempera ture below the dew point For most ambient conditions considerable water vapor is condensed To remove the condensation each compressor with built in aftercooler is supplied with a combination c...

Страница 54: ...d by other electrical equipment The length of wiring from a suitable electrical feed point is critical as voltage drops may impair the performance of the com pressor Cable sizes may vary considerably...

Страница 55: ...r compressor rotation An alternative to this procedure is to set the WS Controller to display P1 separator sump tank pressure Pull out the EMERGENCY STOP button and press once quickly and in successio...

Страница 56: ...4 Installation 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 50 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 57: ...mplete operation capabilities The WS Controller key pad has two main pads for compressor control To start the compressor operation press the green Start pad To stop compressor operation press the red...

Страница 58: ...ressor The upper line will indicate Compressor Status and the name of the temperature pressure or other measure ment The lower line indicates the present reading Refer to Figure 5 7 When you continue...

Страница 59: ...ed to the controller It will blink very slowly if the WS Controller is set up to automatically restart after power failure The green Run mode indicator indicates compressor operation is enabled It lig...

Страница 60: ...5 WS Controller 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 54 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 61: ...s recommended that a general check on the overall compressor be made to assure that the compressor is running properly 6 3 Maintenance after initial 50 hours of operation After the initial 50 hours of...

Страница 62: ...aintenance Refer to Figure 6 2 Air filter maintenance should be per formed when the maintenance gauge shows red with the compressor running full load or once a year whichever comes first If the filter...

Страница 63: ...eight 8 hex head capscrews in 1 in from the cover plate 2 Lift the cover plate from the separator sump tank 3 Remove the separator element 4 Inspect the separator sump tank for rust dirt etc 5 Reinser...

Страница 64: ...er assembly and replace with new assembly 4 Inspect and clean the orifice inside the sight glass blocks The orifice must be removed with an allen wrench 5 Coat lubricate the O rings with silicone grea...

Страница 65: ...sing the coupling element 3 Unwrap the coupling element from the cou pling jaws 4 Install the new element by wrapping it around the jaws engaging the cogs on the element into the jaws 5 Reinstall the...

Страница 66: ...perature to 85 F 29 4 C or less Water cooled only Cooling water flow insufficient Check water lines and valves water cooled only Cooler plugged Clean tubes If plugging persists install water condition...

Страница 67: ...level too high Drain and change Check that the compressor temperature has not dropped below 170 F 76 7 C Pressure relief valve opens repeatedly Defective pressure relief valve Replace Plugged separat...

Страница 68: ...6 Maintenance 3000PB 3700B 4500B 3000PVB 3700VB 4500VB User Manual Notes 02250216 786 R01 62 Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 69: ...Subject to EAR ECCN EAR99 and related export control restrictions...

Страница 70: ...subject to change without prior notice Subject to EAR ECCN EAR99 and related export control restrictions Sullair LLC 3700 East Michigan Boulevard Michigan City IN 46360 USA www sullair com 1 800 SULLA...

Отзывы: