Level Adjustable Shelving System:
Installation Manual
Top/Bottom Bracket VT-DF-E 1820
Slotted Panel Bracket VT-DF-A 1820
Before the installation, read this manual thoroughly for proper fitting.
・
The use in high temperature/humidity environment is not allowed.
・
Check that the installation of the bracket makes it level or plumb and that twisting does not occur.
・
As this product is for indoor use, do not use it outdoors or in the place splashed with water.
・
Ensure sufficient heat insulation when fixing it directly to columns, etc. so that the bracket will not
suffer from heat bridge or due condensation.
This symbol represents
the "Prohibited matters".
This symbol represents
the "Mandatory matters"
to be performed without fail.
・
Use nonslip gloves when carrying the parts. Be careful to secure enough ventilation when using adhesives.
・
Before the delivery, the installation supervisor should check the installation result without fail and repair problems if any.
Safety notice.
<Be sure to observe the following instructions to prevent injury or accident.>
・
Be sure to provide marking before installation.
Checking before the installation
※
If not, be sure to provide reinforcing material. Otherwise the brackets may fall off.
・
Check the quantity of the parts and if any flaws or dents exist.
Our company will not be held responsible for the flaws or dents caused after the installation.
・
Check that the wall on which the brackets for shelves are fixed is strong enough.
・
Check the wall finish to which the Slotted Panel Bracket is fitted (check that it is plumb and even) .
1. Fitting catches
Installing the bracket
after checking the fitting position.
Fit the catches to the necessary number of panels
Fit the catches (VT-DF-C20) to the t20 panel prepared
by the customer with fixing screws according to the illustration
in the same manner as above.
2. Marking of the position to fit the bracket
Check the Package Contents
○
Electric drill, level, driver.
※
Necessary screws shall be prepared by customer.
Tools and screws necessary for the installation.
Bracket fixing screws (Tapping screws of 4 x 50; five pieces. per bracket).
Catch fixing screws (pan-head, truss or bind tapping screws of nominal approx. 4 x 20; 16 pieces per panel).
Slotted Panel
L=1820
Name
Q'ty contained
Shape
1
Bracket
VT-DF-A 1820
Slotted Panel Bracket VT-DF-A 1820
NO.
A
Panel Catch
8
(Panel fixing parts)
VT-DF-C20
B
Top/Bottom
L=1820
Name
Q'ty contained
Shape
1
Bracket
VT-DF-E1820
Top/Bottom Bracket VT-DF-E1820
NO.
A
Panel Catch
8
(Panel fixing parts)
VT-DF-C20
B
After checking the position to fit the top/bottom bracket,
For VT-DS-E1820, five fixing points or so shall be required.
according to the illustration.
drill pilot holes. Then fix the bracket with bracket fixing screws
of the top/bottom bracket as the reference.
Check that there is no unevenness on the wall surface
Without finishing material on the substrates, they will look bad
when the panel is removed.
Mark with level, etc. the position to fit the shelf bracket,
assuming the height of the horizontal line of the upper surface
Therefore applying finishing material is recommended.
on which the bracket is installed.
※
Place the panel on the ends of catches.
20mmpanel
1820mm
Min.105mm
Max.450mm
Finishing material
Reference line
Substrate
(stud, etc.)
3. Fitting the panel and the bracket
4. Illustration of the panel
※
Fit necessary number of panels and A1820s one after
after another in the same manner as above.
Use top bracket for the top panel.
Check that the brackets and panels are level and plumb
and that there is neither unevenness nor gap.
Check that panels can be fixed and removed.
Top Bracket
Fix the panel to the bottom brackets with the lower catch of the panel.
Fix A1820 with pilot holes to the wall with bracket fixing screws.
in the illustration.
For VT-DS-A1820, five fixing points or so shall be required.
Fix VT-DF-A1820 to the upper catch of the panel as shown
and bracket installed