SUGATSUNE LAMP DC Series Скачать руководство пользователя страница 1

Side plate

1

(24)

16

Trigger fix screw

 

Top plate

Adjust

 

±

3

B

A

50

98

(34.5)

13

(88)

20

20

64

(33)

20

Main unit fix screw

Wood door

Wood door

Overlay amount

16

Wood door

Glass process dimensions

A

B

Inset door

88

door end gap

overlay door

88

overlay amount

24

door end gap

Overlay amount

24

DC-100

DAMPER CATCH DC SERIES INSTALLATION MANUAL
(DC-90

DC-90G

DC100

DC-100G)

Thank you for using our product. Before installation, please read this manual thoroughly to ensure correct installation.
Please keep this manual at hand for future reference.

GLASS PROCESS DIMENSIONS

(DC-90G AND DC-100G)
Prepare hole as shown right.

2

×

I

7

Door end

Outside of door

A

32

B

Top plate

Wood door

Main unit fix screw

Trigger fix screw

 

Trigger fix screw 

Glass door

Side plate

Adjust

 

±

3

(34.5)

A

32

A

13

(52.7)

50

18.5

20

16

C

22

24

32

B

11.5

(34.5)

Overlay amount

Side plate

5

Door endgap

8

Door endgap

Top plate

20

B

Mount position

A

B

C

 door end gap 

3

Inset door

overlay door

C

 

overlay 

3

24 

− 

door end gap

overlay

 + 

24

DC-90

 

C:100 to 200 mm

For inset door (glass) 

For overlay door (wood)

For overlay door (wood)

For an inset door, refer to the upper left figure.

( The main body shows DC-90 type and DC90G type. 

Name

/

Item No.

Main body

Trigger

Trigger 
positioning jig

Main unit fix screw

Truss head tapping 

screw 4

×

30

Trigger fix screw 

Truss head tapping 

screw 4

×

16

Face plate

Spacer

Trigger fix screw

Truss head scew 

M4×12

DC-90

1

 

pc

1

 

pc

1

 

pc

2

 

pcs

2

 

pcs

̶

̶

̶

DC-90G

1

 

pc

1

 

pc

1

 

pc

1

 

pc

1

 

pc

2

 

pcs

̶

1

 

pc

1

 

pc

2

 

pcs

DC-100

1

 

pc

1

 

pc

2

 

pcs

2

 

pcs

̶

̶

̶

DC-100G

1

 

pc

1

 

pc

2

 

pcs

̶

1

 

pc

1

 

pc

2

 

pcs

for wood top plate (20mm thick)

Caution:

  

If not followed, injury or damage may result.

The product is designed for indoor use.
Temperature range: 10 to 40°C, Humidity: less than 90%
Do not use it for any purpose other than cabinet. 
Do not use excessive force to the damper. It may cause damage.
This product is a part for furniture. After installation, please check the function and safety of the final product.
Use the hinges without catch.

Meaning of symbols

FOR YOUR SAFE WORK AND CORRECT INSTALLATION

COMPONENT PARTS

INSTALLATION DRAWING

Parts No.

Max. Door Width Max. Door Height Glass thickness  Door Weight

DC - 9 0

− 

4kg

DC - 9 0 G

5

− 

4kg

DC -10 0

1.5 

− 

7kg

DC -10 0 G

4 5 0
4 5 0
6 0 0
6 0 0

600

6 0 0
8 0 0
8 0 0

5

1.5 

− 

7kg

DOOR SPECIFICATION

Warning

Caution

Prohibited

Required