![Sub-Zero VAF433-T Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/sub-zero/vaf433-t/vaf433-t_operating-manual_1388395001.webp)
6
Select number of poles.
7
Clear run hours.
Restore factory defaults
Error Messages
8
Index
Sr.
No.
Description
Para.
1
3
4
5
Network selection either 3P-3W and 3P-4W.
Select PT secondary ratio.
Select PT primary ratio.
2
Select CT primary ratio.
Index
Sr.
No.
Description
User Interface.
Technical Specification.
Parameter setting mode.
Para.
Home Page Screen Description
Home Page Screen Description
Automatic Mode / Manual Mode Settings :
Press A/M mode for 4 seconds to toggle between
Automatic/Manual Mode.
Note : By Default unit operates in automatic mode. In automatic
mode online pages scroll automatically at the rate of 5 sec per
page.In automatic mode if any key is pressed,unit temporarily
switched to manual mode and the appropriate page is displayed.
In Automatic Mode :
1st Screen
Displays Line to Neutral voltage of all
3 Phase
2nd Screen
Displays Line to Line voltage of all 3
Phase
3rd Screen
rpm
4th Screen
Displays current of all 3 Phase
5th Screen
Displays Run Hours
6th Screen
Displays Power Factor of Line to Line
Voltage.
7th Screen
Displays Line to Neutral voltage, current
and frequency of first Phase
8th Screen
Displays line to neutral voltage, current
and frequency of second Phase
10th Screen
Displays average line to neutral voltage,
average current of three phase and
frequency.
11th Screen
Displays average line to line voltage,
average current of three phases and
frequency of present phase.
9th Screen
Displays line to neutral voltage, current
and frequency of third Phase
1. Display Descriptions in 3Ø – 4W :
Operating Manual
VAF433-T
Dimensions & Panel Cutout
Caution for your Safety
Maintenance:
Cleaning: Clean the surface of the controller with a soft
moist cloth. Do not use abrasive detergents, petrol, alcohol or solvents.
WIRING:
The probe and its corresponding wires should
never be
installed in a conduit next to control or power
supply lines. The electrical
wiring should be done as shown in the diagram. The power supply
circuit should be connected to a protection switch. The terminals admit
wires of upto 2.5sq mm.
WARNING:
Improper wiring may cause irreparable damage and
personal injury. Kindly ensure that wiring is done by qualified personnel
only.
Notice:
The information in this document is
subject
to change in order
to improve reliability , design or function without prior notice and does
not represent
a commitment on the part of the company. In no
event will
the company be liable for direct, indirect, special, incidental or
consequential damage arising out of the use or inability to use the
product or documentation, even if advised of the possibility of such
damages. No part of this manual may be reproduced or transmitted in
any form or by any means without the prior written permission of the
company.
Probe :
To give a correct reading, the probe must be installed in a place
protected from thermal influences, which may affect the temperature to
be controlled.
Controller
:Controller should be installed in a place protected by
vibration, water and corrosive gasses and where ambient temperature
does not exceed the values specified in the technical data.
Introduction
Connection Diagram
1
2
3
4
5
6
7
11
12
S1
S2
N
8
9
10
V
R
V
Y
V
B
I
1
I
2
I
3
L
N
230V
S1
S2
S1
S2
18
19
20
V
R
V
B
V
Y
3P4W
3P3W
Technical Specification
Housing
:
Front Cover: Polycarbonate Plastic
Dimensions
:
Frontal : 96 X 96mm, Depth : 61mm
Operating humidity :
20% to 85% (non-condensing)
Measuring Range
: 19 to 865 V AC (L-L)
Input Rated Current
: Nominal 5A AC
PT Primary
: 100 V to 500 kV
Connections
:
Terminal connectors.
<
2.5sq mm terminal only with U-type
Data storage
:
Non-volatile flash memory
Panel Cutout
:
91 X 91mm
lugs.
Display :
3 X 17mm 7 segment White display,
Power Input
:
240 Vac ±20 % , 50/60Hz Standard.
Operating temp. :
0°C to 60°C (non-condensing)
Storage temp :
-25°C to 60°C (non-condensing)
Mounting
:
Flush panel mounting with Fasteners
Protection
:
IP65 Front
Back Cover: ABS Plastic
15 Iconic LEDs for Indication
Wiring Input
:
3ø-4W, 3ø-3W system.
Input Rated Voltage :
5
11 to 00 V AC (L-N)
CT Primary
: 5 A to 10 kA
CT Secondary
: 5 A
PT Secondary
: 100 to 500 V AC (L-L)
Electrical Connection
: 3ø-4W, 3ø-3W, 2ø-3W, 1ø-2W.
Resolution
Current / Voltage
: Resolution depends upon CT,
PT Primary settings
RPM
: 0.1
Run Hour
: 0.1 Hr
Accuracy
± 1% of F.S. ± 2 digits
Current & Average Current :
:
± 0.1 Hz ± 1 digit
Frequency
:
± 1%
Run Hour
± 0.5%
RPM :
Display Scrolling :
Automatic or Manual
Voltage :
± 0.5% of F.S. ± 2 digits.
(Programmable)
Power Consumption :
1.5VA Max
RPM :
1350 to 1950
Pole: 0
(Range: 0-98, selectable in steps
of 2)
Run Hours :
0 to 99999.9 Hrs
Burden :
0.5VA @5A per phase
Frequency :
45-65 Hz
Sr.
No.
Description
1
Electrical parameters like AC Voltage, AC Current,
RPM, Frequency and Power Factor will be seen as Per
screen no and auto or manual mode.Kindly refer Home
Page Descriptor.
2
3
4
Unit KiloVolts
5
Unit Volts
User Interface
11
12
13
14
15
VAF433-T
V r
I h
A M
AVG
1
2
3
4
5
6
7
8
9
10
17
18
19
16
6
7
Kilo Ampere
Ampere
8
9
Unit for Run Hours
Power Factor
Down key/ I/ h :
Press this key for 1 second,
the First Screen
Displays phase current of three phases. Line to
neutral and line to line voltage of three phases are
displayed one by one.
In Normal Mode (Auto/Manual):
Press this key for 3 seconds,
to display Run
Hours (for non zero poles).
In Program Mode:
To increase Parameter
value.
Note:
To return back to current page, press
for 3 seconds.
I
I
h
h
17
Next key :
In Manual Mode:
To scroll for Next Screen.
In Program Mode:
To scroll to Next Parameter.
Note:
Kindly refer ‘Home Page Screen
Description’ for further details.
10
11
12
13
14
15
16
AVG
Frequency units Hertz
Line to Line value of corresponding parameter
Line to Neutral value of First Phase
Average value of corresponding parameter
Line to Neutral value of Second Phase
Line to Neutral value of Third Phase
18
Up key :
19
In Normal Mode (Auto/Manual):
In Program Mode:
To increase Parameter
value.
Note:
To return back to current page, press
for 3 seconds.
Press this key for 1 second.
The First Screen displays line to neutral voltage
of three phases.
The Second Screen displays line to line voltage
of three phases.
Press this key for 3 seconds.
Displays rpm for non zero poles.
V r
Note:
Kindly refer ‘Home Page Screen
Description’ for further details.
Exit key :
In Program Mode:
Press this key for 4 seconds
to toggle
between Automatic/Manual Mode.
To save the changed Parameter and exit to
Normal mode.
In Normal Mode:
A M
Front View
96
96
91mm
91mm
91
Side View
Panel Cutout
All dimensions are in MM.
The VAF is a panel mounted 96 x 96mm Digital Panel Meter for the
measurement of important electrical parameters like AC Voltage, AC
Current, RPM, Frequency and Power Factor VAF can be configured
and Programmed On site for the following :
PT Primary, PT Secondary, CT Primary, CT Secondary (5A or 1A) and
System Type 3 phase 3W or 4W or single phase system.
The front panel has Four keys using which the user can scroll through